Effects of hemoglobin (Hb) E and HbD traits on measurements of glycated Hb (HbA1c) by 23 methods.

نویسندگان

  • Randie R Little
  • Curt L Rohlfing
  • Steve Hanson
  • Shawn Connolly
  • Trefor Higgins
  • Cas W Weykamp
  • Mario D'Costa
  • Veronica Luzzi
  • William E Owen
  • William L Roberts
چکیده

BACKGROUND Glycohemoglobin (GHB), reported as hemoglobin (Hb) A(1c), is a marker of long-term glycemic control in patients with diabetes and is directly related to risk for diabetic complications. HbE and HbD are the second and fourth most common Hb variants worldwide. We investigated the accuracy of HbA(1c) measurement in the presence of HbE and/or HbD traits. METHODS We evaluated 23 HbA(1c) methods; 9 were immunoassay methods, 10 were ion-exchange HPLC methods, and 4 were capillary electrophoresis, affinity chromatography, or enzymatic methods. An overall test of coincidence of 2 least-squares linear regression lines was performed to determine whether the presence of HbE or HbD traits caused a statistically significant difference from HbAA results relative to the boronate affinity HPLC comparative method. Deming regression analysis was performed to determine whether the presence of these traits produced a clinically significant effect on HbA(1c) results with the use of +/-10% relative bias at 6% and 9% HbA(1c) as evaluation limits. RESULTS Statistically significant differences were found in more than half of the methods tested. Only 22% and 13% showed clinically significant interference for HbE and HbD traits, respectively. CONCLUSIONS Some current HbA(1c) methods show clinically significant interferences with samples containing HbE or HbD traits. To avoid reporting of inaccurate results, ion-exchange chromatograms must be carefully examined to identify possible interference from these Hb variants. For some methods, manufacturers' instructions do not provide adequate information for making correct decisions about reporting results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of hemoglobin variants and derivatives on glycohemoglobin determinations, as investigated by 102 laboratories using 16 methods.

Influences of hemoglobin (Hb) variants (HbSS, HbCC, beta-thalassemia, HbAE, HbAS, HbAC, hereditary persistent HbF) and Hb derivatives (carbamylated- and acetylated-Hbs, Schiff base, and those formed in stored blood) on results of glyco-Hb assays by 102 laboratories using 16 different methods were investigated. Affinity chromatography shows deviating results only with homozygous Hb S and C. Corr...

متن کامل

Effects of hemoglobin C and S traits on the results of 14 commercial glycated hemoglobin assays.

Glycated hemoglobin is widely used in the management of diabetes mellitus. At least 300,000 Americans with diabetes mellitus have the hemoglobin (Hb) C or S trait. The accuracy of HbA1c methods can be adversely affected by the presence of these traits. We evaluated the effects of HbC and HbS traits on the results of 14 commercial HbA1c methods that use boronate affinity, enzymatic, immunoassay,...

متن کامل

Glycated Hemoglobin, Gastric Juice Nitric Oxide and Oxidative Stress in Diabetic Patients Infected by Helicobacter Pylori

Abstract Background and Objective: Recently, diabetes mellitus has been known as one of the main cause of upper gastrointestinal symptoms. Since a high prevalence of H. Pylori in diabetic patients has been reported, we aimed to evaluate the level of gastric juice Nitric Oxide (NO°), Oxidative Stress and Glycated Hemoglobin. Material and Methods: In case group, the participants were 60 diabe...

متن کامل

Aberrantly high glycated haemoglobin measurement due to the haemoglobin variant Hb Santa Juana.

Various laboratory and patient-related factors can result in falsely high or low glycated haemoglobin (HbA1c) measurements, and haemoglobin (Hb) variants that interfere with laboratory readings is an important cause of this. We report a case of a rare Hb variant, Hb Santa Juana, manifesting as a falsely high HbA1c in a 62-year-old patient with type 2 diabetes mellitus. The patient presented wit...

متن کامل

A review of variant hemoglobins interfering with hemoglobin A1c measurement.

Hemoglobin A1c (HbA1c) is used routinely to monitor long-term glycemic control in people with diabetes mellitus, as HbA1c is related directly to risks for diabetic complications. The accuracy of HbA1c methods can be affected adversely by the presence of hemoglobin (Hb) variants or elevated levels of fetal hemoglobin (HbF). The effect of each variant or elevated HbF must be examined with each sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 54 8  شماره 

صفحات  -

تاریخ انتشار 2008