Low-Pressure Cardiac Tamponade
نویسندگان
چکیده
Background—Low-pressure cardiac tamponade is a form of cardiac tamponade in which a comparatively low pericardial pressure results in cardiac compression because of low filling pressure. This syndrome is poorly characterized because only isolated cases have been reported. We conducted a study of its clinical and hemodynamic profiles. Methods and Results—From 1986 through 2004, we evaluated all patients at our institution with combined pericardiocentesis and cardiac catheterization. We identified those patients who fulfilled catheterization-based criteria of low-pressure cardiac tamponade and compared their clinical and catheterization data with those of patients with classic tamponade. A total of 1429 patients with pericarditis were evaluated, 279 of whom underwent combined pericardiocentesis and catheterization. Criteria of low-pressure cardiac tamponade were met in 29, whereas 114 had criteria of classic cardiac tamponade. Patients with low-pressure tamponade less frequently had clinical signs of tamponade, but the rate of constitutional symptoms, use of diuretics, and echocardiographic findings of tamponade were similar in both groups. Patients with low-pressure tamponade showed a significant increase in cardiac output after pericardiocentesis, but they usually had less severe cardiac tamponade compared with patients with classic tamponade. Prognosis was related mainly to the underlying disease. Conclusions—Low-pressure cardiac tamponade was identified in 20% of patients with catheterization-based criteria of tamponade. Clinical recognition may be difficult because of the absence of typical physical findings of tamponade in most patients. Although some patients are critically ill, most show a stable clinical condition. However, these patients obtain a clear benefit from pericardiocentesis. (Circulation. 2006;114:945-952.)
منابع مشابه
Low-pressure cardiac tamponade: clinical and hemodynamic profile.
BACKGROUND Low-pressure cardiac tamponade is a form of cardiac tamponade in which a comparatively low pericardial pressure results in cardiac compression because of low filling pressure. This syndrome is poorly characterized because only isolated cases have been reported. We conducted a study of its clinical and hemodynamic profiles. METHODS AND RESULTS From 1986 through 2004, we evaluated al...
متن کاملComparison of the prevalence of pericardial effusion and cardiac tamponade after cardiac surgery with and without chest tube suction in patients referred to Chamran hospital, Isfahan
Background: Pericardial effusion is one of the most important complications of cardiac surgeries. Administration of a low-power suction to the mediastinal or pleural chest tube of patients helps better and constant drainage of pericardial or pleural secretions after surgeries. This technique might change the secretion and discharges of patients and might change the outcomes of surgeries. Metho...
متن کاملPericardial Effusion in an Extreme Low Birth Weight Neonate with Peripherally Inserted Central Catheter
Background: Pericardial effusion and cardiac tamponade are the rare complications of peripherally inserted central catheters (PICC insertion) in extreme low birth weight infants. In this regard, paying attention to these complications is of utmost importance, because they can result in infant death. Case report: The case of our infant is a sa...
متن کاملHemodynamic effects of volume expansion in patients with cardiac tamponade.
BACKGROUND Volume expansion has been proposed as an alternative treatment for cardiac tamponade; however, the scientific evidence for this recommendation is very poor. METHODS AND RESULTS Forty-nine unselected patients (23 males; age 55+/-16 years) with large pericardial effusion and hemodynamic tamponade underwent fluid overload with intravenous administration of 500 mL of normal saline over...
متن کاملCardiac tamponade in left ventricular dysfunction.
Echocardiographic and hemodynamic data were measured in closed-chest dogs during graded cardiac tamponade (pericardial pressure 5, 10, and 15 mm Hg) before and after production of diffuse ischemic left ventricular dysfunction. Left ventricular dysfunction was produced by intracoronary injection of nonradioactive microspheres (54 +/- 3.9 mm diameter). Changes in left atrial pressure with cardiac...
متن کامل