Quantitative rotational tomography with 201Tl and 99mTc 2-methoxy-isobutyl-isonitrile. A direct comparison in normal individuals and patients with coronary artery disease.

نویسندگان

  • J K Kahn
  • I McGhie
  • M S Akers
  • M N Sills
  • T L Faber
  • P V Kulkarni
  • J T Willerson
  • J R Corbett
چکیده

We tested the hypothesis that 99mTc 2-methoxy-isobutyl-isonitrile (99mTc MIBI), a new radiopharmaceutical for myocardial perfusion imaging, provides accurate noninvasive detection of coronary artery disease (CAD). Imaging in patients after exercise and at rest with 99mTc MIBI was compared with imaging after exercise and redistribution with 201Tl in 12 normal subjects and 38 patients with angiographic documentation of CAD (greater than or equal to 50% diameter stenosis). We used single-photon emission computed tomography (SPECT) and computer quantitation of regional tracer distribution. The quality of reconstructed images with 99mTc MIBI judged visually was superior to that of 201Tl in 88% of all studies performed and was comparable in the others. With the limits of normal as 2.5 SD below the mean of gender-matched normal volunteers, 201Tl SPECT identified 32 and 99mTc MIBI identified 36 patients with CAD (p = 0.2). 201Tl SPECT identified 45 of 75 (60%) and 99mTc MIBI identified 59 of 75 (79%) stenosed coronary arteries (p less than 0.05). The quantitative severity of perfusion defects was similar for the two tracers. 201Tl SPECT identified 104 reversibly ischemic myocardial segments compared with 134 with 99mTc MIBI (p less than 0.05). Thus, SPECT myocardial perfusion imaging with 99mTc MIBI and computer quantitation provides an accurate method for the noninvasive detection of significant coronary artery disease. Furthermore, image quality is generally superior to 201Tl, and reversibly ischemic myocardial segments may be better identified with 99mTc MIBI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relations of the myocardial imaging agents 99mTc-MIBI and 201T1 to myocardial blood flow in a canine model of myocardial ischemic insult.

Myocardial imaging with thallium 201 has proven to be an important clinical procedure to assess the severity of the myocardial ischemic insult. Uptake of 201Tl is related to perfusion to and extraction by intact myocardium. Recently, a newer group of agents based on 99mTc alkyl isonitriles has been developed and appears promising for myocardial imaging. Although the distribution of this new age...

متن کامل

Quantitative angiographic measurements of isolated left anterior descending coronary artery stenosis. Correlation with exercise echocardiography and technetium-99m 2-methoxy isobutyl isonitrile single-photon emission computed tomography.

OBJECTIVES This study sought to assess the value of quantitative coronary arteriography in predicting an ischemic response at exercise echocardiography and technetium-99m 2-methoxy isobutyl isonitrile (mibi) single-photon emission computed tomography (SPECT) in patients with single-vessel disease of the left anterior descending coronary artery. BACKGROUND The relation between severity of coro...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Quantitative planar imaging with technetium-99m methoxyisobutyl isonitrile: comparison of uptake patterns with thallium-201.

To compare the myocardial uptake pattern of 99mTc-labeled methoxyisobutyl isonitrile [( 99mTc] MIBI) and 201TI, planar scintigraphy were performed in both patients with documented coronary artery disease and subjects with a low likelihood of disease. Quantitative analysis was employed using a standard interpolative background subtraction algorithm and a new algorithm modified to better accommod...

متن کامل

Technetium-99m hexakis 2-methoxy-2-isobutyl isonitrile and thallium-201 extraction, washout, and retention at varying coronary flow rates in rabbit heart.

Technetium-99m hexakis 2-methoxy-2-isobutyl isonitrile (Tc-MIBI) and thallium-201 extraction, washout, and retention were investigated and compared in 20 isolated, isovolumic, retrograde blood-perfused rabbit hearts at flow rates ranging from 0.5 to 3.5 ml/g wet wt min-1 in the absence of tracer recirculation. Mean Tc-MIBI peak instantaneous extraction was lower (0.55 +/- 0.10, p less than 0.00...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 79 6  شماره 

صفحات  -

تاریخ انتشار 1989