Partial pressure of end-tidal carbon dioxide successful predicts cardiopulmonary resuscitation in the field: a prospective observational study

نویسندگان

  • Miran Kolar
  • Miljenko Križmarić
  • Petra Klemen2
  • Štefek Grmec
چکیده

INTRODUCTION Prognosis in patients suffering out-of-hospital cardiac arrest is poor. Higher survival rates have been observed only in patients with ventricular fibrillation who were fortunate enough to have basic and advanced life support initiated soon after cardiac arrest. An ability to predict cardiac arrest outcomes would be useful for resuscitation. Changes in expired end-tidal carbon dioxide levels during cardiopulmonary resuscitation (CPR) may be a useful, noninvasive predictor of successful resuscitation and survival from cardiac arrest, and could help in determining when to cease CPR efforts. METHODS This is a prospective, observational study of 737 cases of out-of-hospital cardiac arrest. The patients were intubated and measurements of end-tidal carbon dioxide taken. Data according to the Utstein criteria, demographic information, medical data, and partial pressure of end-tidal carbon dioxide (PetCO2) values were collected for each patient in cardiac arrest by the emergency physician. We hypothesized that an end-tidal carbon dioxide level of 1.9 kPa (14.3 mmHg) or more after 20 minutes of standard advanced cardiac life support would predict restoration of spontaneous circulation (ROSC). RESULTS PetCO2 after 20 minutes of advanced life support averaged 0.92 +/- 0.29 kPa (6.9 +/- 2.2 mmHg) in patients who did not have ROSC and 4.36 +/- 1.11 kPa (32.8 +/- 9.1 mmHg) in those who did (P < 0.001). End-tidal carbon dioxide values of 1.9 kPa (14.3 mmHg) or less discriminated between the 402 patients with ROSC and 335 patients without. When a 20-minute end-tidal carbon dioxide value of 1.9 kPa (14.3 mmHg) or less was used as a screening test to predict ROSC, the sensitivity, specificity, positive predictive value, and negative predictive value were all 100%. CONCLUSIONS End-tidal carbon dioxide levels of more than 1.9 kPa (14.3 mmHg) after 20 minutes may be used to predict ROSC with accuracy. End-tidal carbon dioxide levels should be monitored during CPR and considered a useful prognostic value for determining the outcome of resuscitative efforts and when to cease CPR in the field.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial pressure of end-tidal carbon dioxide predicts successful cardiopulmonary resuscitation in the field

Kolar and colleagues contribute an additional and important incentive for rescuers to utilize end-tidal carbon dioxide tensions as a routine monitor to guide management and decision-making during cardiopulmonary resuscitation. They conclude that below-threshold levels of 14 mmHg (1.5 kPa) measured after 20 minutes of cardiopulmonary resuscitation reliably predict that spontaneous circulation ca...

متن کامل

Investigating the Relationship Between End Tidal Carbon Dioxide and Arterial Carbon Dioxide Pressure in Patients With Respiratory Distress Referred to the Emergency Room of Hazrat Rasool Akram Hospital

Background: Measuring End-Tidal Carbon Dioxide (ETCO-2) can be a non-invasive, fast, and reliable method to predict partial pressure of carbon dioxide (PaCO2) in patients with respiratory distress. This method, which can be a suitable substitute to measure PaCO2, is being used in many emergency rooms and operating rooms in developed countries, but its exact relationship with PaCO2 has not been ...

متن کامل

Standardization and Validation of Non-invasive Monitoring of End Tidal Carbon Dioxide in Neonates via Nasal Cannula: An Observational Study

Background: Carbon dioxide (CO2) is a by-product of cellular metabolism, which could be considered as a reflection of metabolism, circulation, and ventilation. Arterial blood gas analysis (ABG) is the gold standard of monitoring for CO2. However, is an expensive method leading to blood loss and iatrogenic anemia. In addition, each sample is only a...

متن کامل

Active decompression improves the haemodynamic state during cardiopulmonary resuscitation.

OBJECTIVE To examine whether use of the active compression-decompression device improves the haemodynamics of cardiopulmonary resuscitation compared with those of conventional cardiopulmonary resuscitation. DESIGN Prospective crossover study. SETTING The accident and emergency department of a university teaching hospital. PATIENTS 36 adult patients with non-traumatic, normothermic, out of...

متن کامل

Is increased positive end-expiratory pressure the culprit? Autoresuscitation in a 44-year-old man after prolonged cardiopulmonary resuscitation: a case report

BACKGROUND The phenomenon of autoresuscitation is rare, yet it is known to most emergency physicians. However, the pathophysiology of the delayed return of spontaneous circulation remains enigmatic. Among other causes hyperinflation of the lungs and excessively high positive end-expiratory pressure have been suggested, but reports including cardiopulmonary monitoring during cardiopulmonary resu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2008