Discrepancies between cardiovascular magnetic resonance and Doppler echocardiography in the measurement of transvalvular gradient in aortic stenosis: the effect of flow vorticity

نویسندگان

  • Julio Garcia
  • Romain Capoulade
  • Florent Le Ven
  • Emmanuel Gaillard
  • Lyes Kadem
  • Philippe Pibarot
  • Éric Larose
چکیده

BACKGROUND Valve effective orifice area EOA and transvalvular mean pressure gradient (MPG) are the most frequently used parameters to assess aortic stenosis (AS) severity. However, MPG measured by cardiovascular magnetic resonance (CMR) may differ from the one measured by transthoracic Doppler-echocardiography (TTE). The objectives of this study were: 1) to identify the factors responsible for the MPG measurement discrepancies by CMR versus TTE in AS patients; 2) to investigate the effect of flow vorticity on AS severity assessment by CMR; and 3) to evaluate two models reconciling MPG discrepancies between CMR/TTE measurements. METHODS Eight healthy subjects and 60 patients with AS underwent TTE and CMR. Strouhal number (St), energy loss (EL), and vorticity were computed from CMR. Two correction models were evaluated: 1) based on the Gorlin equation (MPG(CMR-Gorlin)); 2) based on a multivariate regression model (MPG(CMR-Predicted)). RESULTS MPGCMR underestimated MPGTTE (bias = -6.5 mmHg, limits of agreement from -18.3 to 5.2 mmHg). On multivariate regression analysis, St (p = 0.002), EL (p = 0.001), and mean systolic vorticity (p < 0.001) were independently associated with larger MPG discrepancies between CMR and TTE. MPG(CMR-Gorlin) and MPGTTE correlation and agreement were r = 0.7; bias = -2.8 mmHg, limits of agreement from -18.4 to 12.9 mmHg. MPG(CMR-Predicted) model showed better correlation and agreement with MPGTTE (r = 0.82; bias = 0.5 mmHg, limits of agreement from -9.1 to 10.2 mmHg) than measured MPGCMR and MPG(CMR-Gorlin). CONCLUSION Flow vorticity is one of the main factors responsible for MPG discrepancies between CMR and TTE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of aortic stenosis severity by rest CMR correlates well with stress echocardiography in the setting of low left ventricular flow states

Background Identifying the high-risk subset of patients with severe aortic stenosis (AS) and low transvalvular pressure gradient due to significant left ventricular (LV) impairment has relied on the assessment of the haemodynamic changes in response to flow normalization using pharmacological stress. Although cardiovascular magnetic resonance (CMR) aortic valve area (AVA) derived from planimetr...

متن کامل

Comparison between cardiovascular magnetic resonance and transthoracic doppler echocardiography for the estimation of effective orifice area in aortic stenosis

BACKGROUND The effective orifice area (EOA) estimated by transthoracic Doppler echocardiography (TTE) via the continuity equation is commonly used to determine the severity of aortic stenosis (AS). However, there are often discrepancies between TTE-derived EOA and invasive indices of stenosis, thus raising uncertainty about actual definite severity. Cardiovascular magnetic resonance (CMR) has e...

متن کامل

Aortic Stenosis assessment with a 3-directional phase contrast magnetic resonance technique. Comparison to transthoracic echocardiography

Background Transthoracic Doppler-echocardiography (TTE) is the standard clinical method for diagnosis and staging of aortic stenosis (AS). AS staging is based on measurement of aortic peak velocity, transvalvular gradient, and calculation of aortic valve area. Unidirectional throughplane phase-contrast magnetic resonance imaging (1DPC-MRI) has been widely applied in clinical imaging to quantify...

متن کامل

Magnetic resonance to assess the aortic valve area in aortic stenosis: how does it compare to current diagnostic standards?

OBJECTIVES The purpose of the present study was to evaluate whether magnetic resonance (MR) planimetry of the aortic valve area (AVA) may prove to be a reliable, non-invasive diagnostic tool in the assessment of aortic valve stenosis, and how the results compare with current diagnostic standards. BACKGROUND Current standard techniques for assessing the severity of aortic stenosis include tran...

متن کامل

Analytical modeling of the instantaneous pressure gradient across the aortic valve.

Aortic stenosis is the most frequent valvular heart disease. The mean systolic value of the transvalvular pressure gradient (TPG) is commonly utilized during clinical examination to evaluate its severity and it can be determined either by cardiac catheterization or by Doppler echocardiography. TPG is highly time-dependent over systole and is known to depend upon the transvalvular flow rate, the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013