Comparison of serum digoxin level measurement with acetyl strophanthidin tolerance testing.
نویسندگان
چکیده
Serum digoxin levels (SDL) were compared with tolerance for the rapidly acting cardiac aglycone, acetyl strophanthidin (AS). AS titration tests were performed on 133 patients with diverse cardiac disorders. All were receiving maintenance digoxin. Both exquisite AS sensitivity and tolerance for a 1.0 mg AS were associated with a wide range of SDL values. Concordance and discordance between the two methods in assessing degree of digitalization were evaluated by considering SDL of 1.4 ng/ml to be the mean value for patients without glycoside-induced cardiac arrhythmia. An SDL of <1.5 ng/ml with tolerance for 1.0 mg AS and an SDL of >1.4 ng/ml with sensitivity to 1.0 mg AS or less constituted concordant responses. An SDL of <1.5 ng/ml with intolerance for 1.0 mg or less AS and an SDL of >1.4 ng/ml with tolerance for 1.0 mg AS comprised discordant responses. In 60 of 144 (42%) AS titrations discordant results were observed. Severe pulmonic, coronary, and aortic valvular heart disease, as well as old age, contributed to unusual AS sensitivitv. Titration with AS clarified pharmacologic quantification of SDL by providing insight into optimum therapeutic glycoside dose.
منابع مشابه
Plasma and myocardial digoxin concentrations in patients on oral therapy.
Methods are now available which are sensitive enough to detect digoxin concentration to levels of 5 mug./ml. Hitherto the degree of sensitivity of specific chemical methods was not acceptable for clinical application. Digoxin-specific antibodies have recently been prepared (Butler and Chen, 1967), and a test based on the radioimmunoassay principle has now been used to measure plasma digoxin lev...
متن کاملInspection of Digoxin level in cardiac heart failure patients refer to Taemin Ejtemai and Shohadaye Ashaer clinic
Background: Heart failure is one of the common cardiovascular diseases and digoxin has the positive effect on it. But unfortunately in spite of its positive effect on heart failure therapeutic and toxic level of it in patients is different and close to each other. The aim of this research was determination of digoxin serum level in failur heart patients. Materials and methods: In this cros...
متن کاملOuabain-specific antibodies: immunochemical properties and reversal of Na + , K + -activated adenosine triphosphatase inhibition.
Antibodies with high affinity and specificity for the cardiac glycoside ouabain were raised in rabbits. The antigen used was a conjugate of ouabain linked through its rhamnose moiety to terminal alpha-amino groups of poly D,L alanyl-human serum albumin. Ouabain-specific antibodies were present as early as 3 wk, and rose steadily in titer over the initial 20-33 wk of immunization. Levels as high...
متن کاملAssessment of Abnormal Serum Digoxin Concentration
ABSTRACT Cardiac glycosides have been used in the management of heart failure for more than 200 years and remain the only drug currently available for Long-term ambulatory use that have positive inotropic effect. The relatively narrow therapeutic- index of cardiac glycosides renders them particularly difficult to use, and the clinician should have a detailed understanding of the actions and ph...
متن کاملPlasma concentration and urinary excretion kinetics of acetyl strophanthidin.
The pharmacokinetics of acetyl strophanthidin (AS) were studied in dogs and human subjects by the use of a newly developed radioimmunoassay. This method has a sensitivity of 0.1 ng of AS per ml and is applicable to direct measurement of AS in unextracted plasma, urine, or bile. After administration of a single intravenous (i.v.) dose of 1.0 mg of AS to 17-25-kg mongrel dogs, the principal expon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 49 6 شماره
صفحات -
تاریخ انتشار 1974