Progress Report on Proton Dosimetry at NPL
نویسندگان
چکیده
A Strategic Research project was performed at NPL with the aim of investigating issues and potential improvements for light-ion dosimetry. The objectives of the project were: a literature survey, testing a number of dosimeters in the proton therapy beam of Clatterbridge Centre of Oncology (CCO), measurement of dose distributions, measurement and calculation of detector perturbations, explore the use of Monte Carlo simulations for the calculation of particle spectra, stopping power ratios and detector perturbation factors. All the work performed in this project, including a literature review of around two hundred papers on proton and light-ion reference dosimetry, is prepared for publication as an internal NPL report [1].
منابع مشابه
IPEM guidelines on dosimeter systems for use as transfer instruments between the UK primary dosimetry standards laboratory (NPL) and radiotherapy centres.
United Kingdom dosimetry codes of practice have traditionally specified one electrometer for use as a secondary standard, namely the Nuclear Enterprises (NE) 2560 NPL secondary standard therapy level exposure meter. The NE2560 will become obsolete in the foreseeable future. This report provides guidelines to assist physicists following the United Kingdom dosimetry codes of practice in the selec...
متن کاملIn vivo proton dosimetry using a MOSFET detector in an anthropomorphic phantom with tissue inhomogeneity
When in vivo proton dosimetry is performed with a metal-oxide semiconductor field-effect transistor (MOSFET) detector, the response of the detector depends strongly on the linear energy transfer. The present study reports a practical method to correct the MOSFET response for linear energy transfer dependence by using a simplified Monte Carlo dose calculation method (SMC). A depth-output curve f...
متن کاملReference dosimetry on TomoTherapy: an addendum to the 1990 UK MV dosimetry code of practice.
The current UK code of practice for high-energy photon therapy dosimetry (Lillicrap et al 1990 Phys. Med. Biol. 35 1355-60) gives instructions for measuring absorbed dose to water under reference conditions for megavoltage photons. The reference conditions and the index used to specify beam quality require that a machine be able to set a 10 cm × 10 cm field at the point of measurement. TomoTher...
متن کاملProton beam dosimetry by CR-39 track-etched detector
Background: High and intermediate energy protons are not able to form a track in a solid state nuclear track detector (SSNTD) directly. However, such tracks can be formed through secondary particles created during primary radiation nuclear reactions in a SSNTD. Materials and Methods: The protons with primary energies of 9.6 and 30 MeV available at the cyclotron accelerator with corresponding lo...
متن کاملComment on 'Proton beam monitor chamber calibration'.
We comment on a recent article (Gomà et al 2014 Phys. Med. Biol. 59 4961-71) which compares different routes of reference dosimetry for the energy dependent beam monitor calibration in scanned proton beams. In this article, a 3% discrepancy is reported between a Faraday cup and a plane-parallel ionization chamber in the experimental determination of the number of protons per monitor unit. It is...