Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry
نویسندگان
چکیده
AIMS To collect information on the use of the Reveal implantable loop recorder (ILR) in the patient care pathway and to investigate its effectiveness in the diagnosis of unexplained recurrent syncope in everyday clinical practice. METHODS AND RESULTS Prospective, multicentre, observational study conducted in 2006-2009 in 10 European countries and Israel. Eligible patients had recurrent unexplained syncope or pre-syncope. Subjects received a Reveal Plus, DX or XT. Follow up was until the first recurrence of a syncopal event leading to a diagnosis or for ≥1 year. In the course of the study, patients were evaluated by an average of three different specialists for management of their syncope and underwent a median of 13 tests (range 9-20). Significant physical trauma had been experienced in association with a syncopal episode by 36% of patients. Average follow-up time after ILR implant was 10±6 months. Follow-up visit data were available for 570 subjects. The percentages of patients with recurrence of syncope were 19, 26, and 36% after 3, 6, and 12 months, respectively. Of 218 events within the study, ILR-guided diagnosis was obtained in 170 cases (78%), of which 128 (75%) were cardiac. CONCLUSION A large number of diagnostic tests were undertaken in patients with unexplained syncope without providing conclusive data. In contrast, the ILR revealed or contributed to establishing the mechanism of syncope in the vast majority of patients. The findings support the recommendation in current guidelines that an ILR should be implanted early rather than late in the evaluation of unexplained syncope.
منابع مشابه
The implantable loop recorder-an important addition to the armentarium in the management of unexplained syncope.
INTRODUCTION Unexplained syncope is a common condition with a significant impact both on the patient and on healthcare expenditure. Often, the diagnosis is hampered due to the temporary sporadic nature of the symptoms. Conventional monitoring methods have a low yield for identifying an abnormality during a spontaneous event. The implantable loop recorder (ILR), often underutilised, is an import...
متن کاملImplantable loop recorder is an effective diagnostic tool for unexplained syncope.
INTRODUCTION Patients with cardiac syncope have a significantly higher mortality than patients with syncope of non-cardiac causes, while patients with syncope of unknown aetiology constitute an intermediate risk group, presumably because this group is mixed, which suggests that further diagnostic testing is warranted. MATERIAL AND METHODS This was a retrospective single-centre study evaluatin...
متن کاملCosts of unstructured investigation of unexplained syncope: insights from a micro-costing analysis of the observational PICTURE registry
AIMS The observational PICTURE (Place of Reveal In the Care pathway and Treatment of patients with Unexplained Recurrent Syncope) registry enrolled 570 patients with unexplained syncope, documented their care pathway and the various tests they underwent before the insertion of an implantable loop recorder (ILR). The aims were to describe the extent and cost of diagnostic tests performed before ...
متن کاملUse of Implantable Loop Recorders to Unravel the Cause of Unexplained Syncope
Syncope is a symptom of many underlying disease states, which range from the relatively benign to the life threatening. There are numerous investigations done for patients with recurrent unexplained syncope which may have very low yield when it comes to making a definitive diagnosis. Recently, the implantable loop recorder (ILR) for continuous monitoring of the cardiac rhythm has been launched ...
متن کاملImplantable Loop Recorder in Diagnosis of Unexplained Syncope
Implantable loop recorder is a diagnostic method in cardiology, having a role in revealing the cause of recurrent unexplained syncope. For automatic recording, the device is equipped with bradycardia and tachycardia programmable options. Battery capacity is 14 months. The aim of the study was to investigate the use of loop recorder in the diagnosis of unexplained syncope. The study enrolled the...
متن کامل