MyoRing treatment of myopia
نویسنده
چکیده
INTRODUCTION Laser Vision Correction is not always possible for the treatment of myopia. The aim of this paper is to present results after MyoRing implantation in myopic eyes who in their majority were not eligible for LVC. Safety, effectivity and patient selection is discussed. The aim of the treatment was to be spectacle independent in everyday-life. MATERIALS AND METHODS 19 myopic eyes of 12 patients ranging from -2.25 to -16.5 dioptres (D) in sphere and from 0 to -4D in cylinder were analyzed. RESULTS After treatment, 84% of the eyes reached uncorrected distance visual acuity (UDVA) of 0.5 or better, 42% reached UDVA of 0.8 or better and 16% reached UDVA of 1.0 or better. Before treatment, no eye reached UDVA of 0.5 or better. Corrected distance visual acuity (CDVA) preoperatively and postoperatively did not differ. The treatment changed the average spherical equivalent from -10.27D to -0.93D. Efficacy index was 0.76 and safety index was 1.02. CONCLUSION MyoRing implantation for myopia is safe and effective with highly satisfied patents in a particular subgroup of myopic patients. Patient selection is important.
منابع مشابه
Full-ring Intrastromal Corneal Implantation for Correcting High Myopia in Patients with Severe Keratoconus
The aim of this study was to evaluate the effect of the mechanical implantation of a MyoRing in patients with severe keratoconus and high myopia. The study involved 32 eyes of 32 patients (14 men and 18 women; mean age: 29.6 ± 6.7; age range: 20 - 44). The patients underwent MyoRing implantation with mechanical dissection using a Pocket Maker microkeratome, and outcomes were assessedat3 months ...
متن کاملBiomechanics of Corneal Ring Implants
PURPOSE To evaluate the biomechanics of corneal ring implants by providing a related mathematical theory and biomechanical model for the treatment of myopia and keratoconus. METHODS The spherical dome model considers the inhomogeneity of the tunica of the eye, dimensions of the cornea, lamellar structure of the corneal stroma, and asphericity of the cornea. It is used in this study for calcul...
متن کاملCharacteristics of Astigmatism after MyoRing Implantation
Considering the rising number of MyoRing implantation procedures in keratoconic corneas and the refractive outcomes associated with this treatment modality, this study aimed to evaluate and compare the magnitude and axis orientation of total and corneal astigmatism between before and after MyoRing implantation in 34 eyes of 28 patients with keratoconus (KCN) (mean age: 29.41 ± 7.0 years). The i...
متن کاملLong-term results of MyoRing treatment of keratoconus☆
PURPOSE To study long-term results of MyoRing treatment of keratoconus. METHODS Retrospective study of MyoRing implantation into a corneal pocket for keratoconus. RESULTS Corneal thickness at the thinnest point remained unchanged, SIM K's, manifest sphere and cylinder were significantly improved at the first follow-up 9 months postoperatively and remained stable until the last follow-up abo...
متن کاملPredictability, Stability and Safety of MyoRing Implantation in Keratoconic Eyes During One Year Follow-Up
Purpose: To assess the stability of visual and refractive outcomes that was compared between three and 12 months after MyoRing implantation in moderate and severe keratoconus Methods: This study included 54 eyes of 50 patients (27 males and 23 females) with stage II and III keratoconus who underwent MyoRing (Dioptex GmbH) implantation. Clinical outcomes including uncorrected distance visual acu...
متن کامل