Metabolic Viabilit in Myocardium With Persistent 24-Hour Single-Photon Emission Computed Tomography 201T1 Defects
نویسندگان
چکیده
Background. Four-hour "1lT redistribution images underestimate myocardial viability in patients with coronary artery disease (CAD). Because 4-hour defects often redistribute late, delayed imaging may enhance assessment of tissue viability. Myocardial metabolic activity was therefore assessed with positron emission tomography (PET) in 26 CAD patients with impaired ventricular function (ejection fraction, 32.1±13.9%o) and 24-hour single-photon emission computed tomography (SPECT) `4lTI defects. Methods and Results. On circumferential profile analysis, PET ischemia was defined by preserved glucose metabolism in hypoperfused myocardium, and PET infarction was defined by concordant reductions in perfusion and metabolism. On 19 stress-redistribution and seven rest-redistribution SPECT studies, four observers visually scored `'TI activity in eight segments on a scale from 0 (normal) to 3 (complete defect). Using an improvement in visual score .0.75 to define redistribution, there were 100 fixed, 17 partially reversible, and 12 completely reversible defects. PET identified tissue metabolic activity in 51 (51%o) segments with fixed defects (21 PET ischemia, 30 PET normal) and nine (53%o) segments with partially reversible defects (five PET ischemia, four PET normal). When grouped by 24-hour score, the proportion of fixed defects with metabolic activity varied from 84% (scores <1.4) to 15% (scores >2.6). For partially reversible defects, only 53% with scores <2.0 and one of two with scores >2.0 were considered metabolically viable on PET. Of 12 completely reversible defects, six (50%) were normal, five (42%) had PET ischemia, and one (8%) had PET infarction. The proportion of fixed defects with metabolic activity did not depend on whether a rest or stress study was performed or on the change in visual score used to define `'TI redistribution (0.25, 0.50, 0.75, and 1.00). Conclusions. In CAD patients, PET identifies glucose metabolic activity in the majority of fixed 24-hour ""T1 defects. However, very severe (near-complete) 24-hour `'TI defects are less likely to exhibit metabolic activity on PET imaging than are defects with less-pronounced reductions in segmental `0'TI activity. (Circulation 1992;86:1357-1369)
منابع مشابه
Visualisation of exercise-induced ischaemia of the right ventricle by thallium-201 single photon emission computed tomography.
OBJECTIVE Exercise thallium-201 (201T1) single photon emission computed tomography (SPECT) has been used to detect potential ischaemia in the left ventricular myocardium but not in the right ventricle. The purpose of this study was to establish the clinical usefulness of a right ventricular polar map of 201T1 SPECT for visualisation of exercise-induced right ventricular ischaemia. METHODS Myo...
متن کاملA study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography
Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-car...
متن کاملQuantification of myocardial infarct size by thallium-201 single-photon emission computed tomography: experimental validation in the dog.
To evaluate the potential advantages of thallium-201 (201T1) single-photon emission computerized tomography (SPECT) to assess myocardial infarct size in the experimental animal, six normal dogs and 14 dogs with 6 to 8 hr closed-chest coronary occlusion (eight left anterior descending and six left circumflex) were studied. Ten minutes after intravenous administration of 2 mCi of 201T1, 30 projec...
متن کاملExercise four hour redistribution thallium-201 single photon emission computed tomography and exercise induced ST segment elevation in detecting the viable myocardium in patients with acute myocardial infarction.
OBJECTIVE To investigate the specificity and sensitivity of the combination of redistribution in exercise thallium-201 single photon emission computed tomography (SPECT) and exercise induced ST elevation for detecting the viable myocardium in patients with acute myocardial infarction. DESIGN 37 patients were studied within seven weeks of onset of Q wave myocardial infarction (anterior in 22, ...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -