An automatic delineation method for bone marrow absorbed dose estimation in 89Zr PET/CT studies
نویسندگان
چکیده
BACKGROUND The study aims to develop and validate an automatic delineation method for estimating red bone marrow (RM) activity concentration and absorbed dose in (89)Zr positron emission tomography/computed tomography (PET/CT) studies. Five patients with advanced colorectal cancer received 37.1 ± 0.9 MBq [(89)Zr] cetuximab within 2 h after administration of a therapeutic dose of 500 mg m(-2) unlabelled cetuximab. Per patient, five PET/CT scans were acquired on a Gemini TF-64 PET/CT scanner at 1, 24, 48, 96 and 144 h post injection. Low dose CT data were used to manually generate volumes of interest (VOI) in the lumbar vertebrae (LV). In addition, LV VOI were generated automatically using an active contour method in a low dose CT. RM activity was then determined by mapping the low dose CT-derived RM VOI onto the corresponding PET scans. Finally, these activities were used to derive residence times and, subsequently, the self and total RM absorbed doses using OLINDA/EXM 1.1. RESULTS High correlations (r (2) > 0.85) between manual and automated VOI methods were obtained for both RM activity concentrations and total absorbed doses. On average, the automatic method provided values that were lower than 5 % compared to the manual method. CONCLUSIONS An automated and efficient VOI method, based on an active contour approach, was developed, enabling accurate estimates of RM activity concentrations and total absorbed doses.
منابع مشابه
Pharmacokinetic studies and human absorbed dose estimation of 68Ga-(4 {[(bis (phosphonomethyl)) carbamoyl] methyl}-7,10-bis(carboxymethy l) -1,4,7,10-tetraazacyclododec-1-yl) acetic acid
Background: In this study, human absorbed dose of a newly introduced bone imaging agent, 68Ga-(4-{[(bis(phosphonomethyl))carbamoyl]methyl}-7,10-bis(carboxymethyl)-1,4,7,10-tetraazacyclododec-1-yl) acetic acid (68Ga-BPAMD), was estimated based on the rats data. Materials and Methods: 68Ga was obtained from the 68Ge/68Ga generator and it's radionuclidic and radiochemical purities were investigate...
متن کاملValidation of simplified dosimetry approaches in ⁸⁹Zr-PET/CT: the use of manual versus semi-automatic delineation methods to estimate organ absorbed doses.
PURPOSE Increasing interest in immuno-positron emission tomography (PET) studies requires development of dosimetry methods which will provide accurate estimations of organ absorbed doses. The purpose of this study is to develop and validate simplified dosimetry approaches for (89)Zirconium-PET (Zr-PET)/computed tomography (CT) studies. METHODS Five patients with advanced colorectal cancer rec...
متن کاملHuman organ absorbed dose estimation of 166Ho-BPAMD complex based on biodistribution data of male Syrian rats
Introduction: Recently, 166Ho-BPAMD was introduced as a suitable agent for bone marrow ablation. The aim of this study was to estimate the absorbed dose of this novel agent in the human organs which is necessary before the clinical application. Methods: 166Ho was produced by direct irradiation of 165Ho in the research reactor. 250 µg...
متن کاملEstimation of fetal absorbed dose from low-dose attenuation-correction CT in PET / CT imaging by using the Body Builder Phantom
One of the methods of studying the physiology and metabolism of important tissues such as the heart, brain and cancer tumors is the use of PET/CT System. A small number of patients are pregnant women who undergo a PET/CT scan due to lack of knowledge about pregnancy or due to dire clinical need. The final dose received by the fetus is based on three factors: the absorbed dose of the fetal tissu...
متن کاملMonte Carlo radiography simulation for assessment of absorbed radiation dose in femur bone marrow during X-ray radiography for constant mAs and AEC techniques
Background: The purpose of this study was to find the accurate absorbed dose in the femur bone marrow during the X-ray radiography for constant mAs and AEC techniques. Materials and Methods: The DOSXYZnrc was used to simulate radiation doses in two human femurs during diagnostic radiography. EGSnrc phantoms produced from actual CT images of human femurs were modified by adding seven micrometre ...
متن کامل