Determination of Chloronicotinyl Insecticides in Salad Vegetables by LC/MSD TOF and LC/MSD Trap Application
نویسندگان
چکیده
This work examines the feasibility of liquid chromatography/mass spectrometry (LC/MS) time-of-flight (TOF) in conjunction with LC/MSD ion trap to analyze chloronicotinyl insecticides: acetamiprid, imidacloprid, and thiacloprid, in four salad vegetables: tomatoes, peppers, lettuce, and cucumbers. Included in this report are the LC/MSD TOF and LC/MSD Trap spectra of the three chloronicotinyl insecticides, the TOF empirical formula determination, and MS/MS fragmentation and diagnostic ion(s) for the chloronicotinyl insecticides in pure solvent, and in the matrices of all four salad vegetables. Also included is a detailed procedure for sample preparation and recovery of the insecticides from the salad vegetables, spectral quality at minimum detection level (MDL), linearity, and quantitation of the insecticides in pure solvent and in the four vegetable extracts for TOF and Trap. Results of the analysis of real samples from the marketplace for these insecticides in the salad vegetables are also presented.
منابع مشابه
Quantitation and accurate mass analysis of pesticides in vegetables by LC/TOF-MS.
A quantitative method consisting of solvent extraction followed by liquid chromatography/time-of-flight mass spectrometry (LC/TOF-MS) analysis was developed for the identification and quantitation of three chloronicotinyl pesticides (imidacloprid, acetamiprid, thiacloprid) commonly used on salad vegetables. Accurate mass measurements within 3 ppm error were obtained for all the pesticides studi...
متن کاملScreening and Confirmation of Anabolic Steroids Using Accurate Mass LC/MS Application
The use of the Agilent LC/MSD TOF, an orthogonal-axis time-of-flight (oa-TOF) mass spectrometer, equipped with an atmospheric pressure chemical ionization (APCI) source, is described for the analysis of four anabolic steroids and one internal standard, in urine extracts at a 1–2 ng/mL concentration. The high degree of mass accuracy (<3 ppm) of the TOF instrument allows for both excellent confir...
متن کاملDetermination of EU-Banned Disperse Dyes by LC/MSD TOF
Accurate mass measurements are used to both confirm the presence of a compound and help identify unknowns. Furthermore, high-mass accuracy enables the user to generate very narrow extracted ion chromatograms, enabling excellent quantitation. This application note describes the use of the Agilent liquid chromatograph/ mass selective detector time-of-flight (LC/MSD TOF) instrument to identify and...
متن کاملAutomated Targeted Screening of Leachables in Pharmaceutical QC Labs Using the Agilent LC/MSD XT and Agilent OpenLAB CDS
This Application Note describes a routine analysis workflow for pharmaceutical QA/QC labs. Organic nonvolatile leachables from ophthalmic drug products were identified and quantified using an Agilent Liquid Chromatograph/Mass Selective Detector XT (LC/MSD XT), based on single quadrupole technology, with the Agilent 1260 Infinity II LC system and Agilent OpenLAB CDS Software. The newly designed ...
متن کاملDetermination of Acrylamide in Raw and Drinking Waters
A liquid chromatography/mass spectrometry (LC/MS) method is developed for the fast, high throughput quantitation of acrylamide in drinking water using online sample extraction coupled with the Agilent liquid chromatography/mass selective detector time-of-flight (LC/MSD TOF). The limit of quantitation of 0.25 μg/L meets the World Health Organization guideline for the maximum safe level concentra...
متن کامل