Structure and composition of rat precorneal tear film. A study by an in vivo cryofixation.

نویسندگان

  • H B Chen
  • S Yamabayashi
  • B Ou
  • Y Tanaka
  • S Ohno
  • S Tsukahara
چکیده

PURPOSE To visualize the in vivo structure and to investigate the composition of rat precorneal tear film. METHODS An in vivo cryofixation with freeze substitution method of electron microscopy was used for the study. For light and transmission electron microscopy, a small amount of aluminum powder was used as a tracer spread on the corneal surface. The eyeballs were immediately and quickly frozen by pouring an isopentane-propane mixture cooled by liquid nitrogen directly over the eyes. For scanning electron microscopy, the corneal surface was freeze-fractured after the cryofixation. The specimens were then freeze-substituted and prepared conventionally for microscopic observation. RESULTS The tear film appeared as a layer of homogeneous and fine network-like structures varying from 2 to 6 microns in thickness on the corneal surface, with a membrane-like layer covering its surface. The aluminum powder was located on the surface of the tear film. The tear film could be removed completely by applying 10% or 20% acetylcysteine, but not by phosphate buffer. CONCLUSIONS The in vivo structure of the rat tear film is composed primarily of mucus, with a lipid layer covering its surface but without a free aqueous layer. The "three layers theory" of tear film structure requires revisions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: viscoelastic increases tear film stability.

PURPOSE To develop a safe, noninvasive, noncontact, continuous in vivo method to measure the dehydration rate of the precorneal tear film and to compare the effectiveness of a viscoelastic agent in maintaining the precorneal tear film to that of a balanced salt solution. METHODS Software was designed to analyze the corneal reflection produced by the operating microscope's coaxial illumination...

متن کامل

Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.

PURPOSE To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9...

متن کامل

Study of precorneal tear film thickness and structure by interferometry and confocal microscopy.

Past measurements of precorneal tear film thickness in rabbits and humans gave values of 4-7 microns. These have been the accepted values. However, measurements presented in this report are much higher. Earlier techniques may have changed film thickness or not have fully included the layer containing mucus. Little is known about the mucus component. Thickness was measured in freshly killed anim...

متن کامل

A novel method for pachymetry mapping of human precorneal tear film using Pentacam with fluorescein.

PURPOSE To report a novel method for pachymetry mapping of human precorneal tear film using Pentacam. METHODS Precorneal tear film is routinely undetected by Pentacam but could be well visualized with the aid of fluorescein. Twenty patients with dry eye and 20 age-matched control subjects with normal eyes were enrolled in this prospective study. The right eye of each subject was scanned once ...

متن کامل

Measuring of corneal thickness of contact lens wearers with keratoconus and keratoplasty by means of optical coherence tomography (OCT).

To measure the corneal thickness and the depth of the precorneal tear film of contact lens wearers with keratoconus or keratoplasty and to reconfirm the identification and classification of the keratoconus with optical coherence tomography (OCT). The cornea and precorneal tear film of 123 eyes with keratoconus, of 39 eyes after keratoplasty and 8 eyes after LASIK were examined with an OCT (Zeis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 1997