Automatic weaning from mechanical ventilation using an adaptive lung ventilation controller.

نویسندگان

  • D M Linton
  • P D Potgieter
  • S Davis
  • A T Fourie
  • J X Brunner
  • T P Laubscher
چکیده

STUDY OBJECTIVE To evaluate a new method of closed-loop mechanical ventilation using an adaptive lung ventilation (ALV) controller in patients with different pathologic causes of respiratory failure at a time when they first met standard weaning criteria. STUDY DESIGN Prospective, open, selected case study. SETTING The 10-bed, multidisciplinary respiratory intensive care unit at Groote Schuur hospital, which is a teaching unit of the University of Cape Town. PATIENTS Twenty-seven patients (9 patients in each of 3 groups: normal lungs, parenchymal lung disease, and COPD) who required prolonged mechanical ventilation and who met standard weaning criteria were included. Our institutional committee for ethical research approved the study and informed consent was obtained. INTERVENTIONS The patients were mechanically ventilated and had daily measurements of vital capacity, respiratory rate, and arterial blood gas analysis until they met standard weaning criteria. On the day that each patient met the weaning criteria, a closed loop control algorithm providing ALV was implemented on a modified ventilator (Hamilton AMADEUS) with a PC-based lung function analyzer. After measuring gross alveolar ventilation, patients were placed in ALV and ventilatory and hemodynamic parameters were measured at baseline, 5 min, 30 min, and 2 h. Pertinent parameters measured included airway pressures, pressure support levels, respiratory rates, rapid shallow breathing indices, airway resistance indices, and patient respiratory drive and work indices. MEASUREMENTS AND RESULTS In 22 patients, ALV reduced pressure support to 5 cm H2O and an intermittent mandatory ventilation rate of 4 breaths/min within 30 min, and all but 1 of these patients were successfully extubated within 24 h. In four patients, pressure support was maintained by ALV at a mean level of 14.6 cm H2O +/- for 2 h and these patients were recorded as having failed to wean. There was a measurable difference in an index of airway resistance relative to muscular activity between the successfully weaned and failed wean patients with COPD during the attempted wean by the ALV controller. CONCLUSIONS ALV will provide a safe, efficient wean and will respond immediately to inadequate ventilation in patients when standard weaning criteria are met.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery

Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...

متن کامل

Weaning from mechanical ventilation: why are we still looking for alternative methods?

Most patients who require mechanical ventilation for longer than 24 hours, and who improve the condition leading to the indication of ventilatory support, can be weaned after passing a first spontaneous breathing test. The challenge is to improve the weaning of patients who fail that first test. We have methods that can be referred to as traditional, such as the T-tube, pressure support or sync...

متن کامل

The effect of protocol of weaning from mechanical ventilation on gastrointestinal function in people undergoing coronary artery bypass graft surgery (CABG)

Abstract Aim. The aim of this study was to examine the effect of protocol of weaning from mechanical ventilation on the gastrointestinal function in people undergoing CABG. Background. The most common problems after cardiac surgery in the intensive care unit are change in vital signs, respiratory problems, unsuccessful separation from mechanical ventilation, and gastrointestinal problems. Due t...

متن کامل

حسابرسی مراقبت‌های پرستاری مرتبط با جداسازی نوزادان از دستگاه تهویه مکانیکی در بخش‌های مراقبت‌های ویژه نوزادان

Background & Aim: Mechanical ventilation is one of the most common treatments in neonatal intensive care unit and is however associated with many complications. One of the ways to reduce complications is providing nursing care according to standards. This study was conducted with the aim of determining the conformity of nursing care related to weaning neonates from mechanical ventilation to the...

متن کامل

A randomized controlled trial of adaptive support ventilation mode to wean patients after fast-track cardiac valvular surgery.

BACKGROUND Adaptive support ventilation can speed weaning after coronary artery surgery compared with protocolized weaning using other modes. There are no data to support this mode of weaning after cardiac valvular surgery. Furthermore, control group weaning times have been long, suggesting that the results may reflect control group protocols that delay weaning rather than a real advantage of a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 106 6  شماره 

صفحات  -

تاریخ انتشار 1994