Effect of Hemorrhage on Hepatic Blood Flow Determined by Radioactive Colloidal Chromic Phosphate Removal

ثبت نشده
چکیده

In a group of IS anesthetized dogs hepatic blood flow measured by the BSP removal technio of Bradley and the radioactive colloidal chromic phosphate disappearance method of Dobson gave comparable results of 3S.7 and 38.3 liil./Kg./niin. respectively. In response to acute hemorrhage of 25 ml./Kg., hepatic blood flow fell from 42.3 to 35.4 ml./Kg. A more severe hemorrhage of"33 ml./Kg. produced a more profound decrease of hepatic blood flow, from 43.4 to 20.S iiil./Kg./min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Hemorrhage on Hepatic Blood Flow Determined by Radioactive Colloidal Chromic Phosphate Removal

In a group of IS anesthetized dogs hepatic blood flow measured by the BSP removal technio of Bradley and the radioactive colloidal chromic phosphate disappearance method of Dobson gave comparable results of 3S.7 and 38.3 liil./Kg./niin. respectively. In response to acute hemorrhage of 25 ml./Kg., hepatic blood flow fell from 42.3 to 35.4 ml./Kg. A more severe hemorrhage of"33 ml./Kg. produced a...

متن کامل

Effect of Hemorrhage on Hepatic Blood Flow Determined by Radioactive Colloidal Chromic Phosphate Removal

In a group of IS anesthetized dogs hepatic blood flow measured by the BSP removal technio of Bradley and the radioactive colloidal chromic phosphate disappearance method of Dobson gave comparable results of 3S.7 and 38.3 liil./Kg./niin. respectively. In response to acute hemorrhage of 25 ml./Kg., hepatic blood flow fell from 42.3 to 35.4 ml./Kg. A more severe hemorrhage of"33 ml./Kg. produced a...

متن کامل

Effect of hemorrhage on hepatic blood flow determined by radioactive colloidal chromic phosphate removal.

In a group of IS anesthetized dogs hepatic blood flow measured by the BSP removal technio of Bradley and the radioactive colloidal chromic phosphate disappearance method of Dobson gave comparable results of 3S.7 and 38.3 liil./Kg./niin. respectively. In response to acute hemorrhage of 25 ml./Kg., hepatic blood flow fell from 42.3 to 35.4 ml./Kg. A more severe hemorrhage of"33 ml./Kg. produced a...

متن کامل

Studies of the reticuloendothelial system (RES). I. Measurement of the phagocytic capacity of the RES in man and dog.

In 1884, Metchnikoff (1) presented his studies of phagocytosis and concluded that the process was a general reaction that removed particulate matter from the circulation. Highly mobile cells, the polymorphonuclear leukocytes, were observed to ingest microorganisms and other particulate matter, such as pus, corpuscular elements of extravasated blood, and foreign cells. In addition to these circu...

متن کامل

The Disappearance Rate of Colloidal Radiogold from the Circulation

The bromsulphalein method of estimating liver blood flow in man first introduced by Bradley, Ingelfinger, Bradley, and Curry (1) has proved to be a very useful tool in the hands of various workers. Though there is not complete agreement as to the question of extrahepatic dye loss and the problem of a single hepatic vein sample not being entirely representative of all the blood leaving the liver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005