Counterpulsation from the skeletal muscle ventricle and the intraaortic balloon pump in the normal and failing circulations.
نویسندگان
چکیده
BACKGROUND The intra-aortic balloon pump (IABP) is the device that is in most common use to provide cardiovascular support. A skeletal muscle ventricle (SMV) was configured to produce counterpulsation in the thoracic aorta similar to that obtained with an IABP. The hemodynamic effects of an IABP and a SMV in the same animal and in both normal and failing circulations were assessed. METHODS AND RESULTS SMVs were connected to and IABPs were placed in the thoracic aorta of 12 anesthetized pigs. Hemodynamic parameters during the IABP- or the SMV-assisted beat were compared with those during the preassist beat. Acute heart failure was induced in 6 of the pigs by snaring the left anterior descending coronary artery (LAD). The hemodynamic effects of the IABP and the SMV were then reassessed. In the assisted cycles, SMV activation increased the mean aortic diastolic pressure (MADP) by 26.5+/-3.5%, the mean diastolic LAD flow by 48.4+/-7.2%, and endocardial viability ratio (EVR) by 31.6+/-3.8% (P<0.0001). In the same animals, IABP assist increased MADP by 19.8+/-2.3%, mean diastolic LAD flow by 37.2+/-3.9%, and EVR by 21.4+/-3.0% (P<0.0001). Under acute heart failure conditions, both SMV and IABP assist significantly increased MADP, mean diastolic LAD flow, and EVR. CONCLUSIONS In both the normal and failing circulations, the SMV was an effective counterpulsator, providing cardiac assist that was at least equal to that available from an IABP. The SMV may therefore provide the proven benefits of an IABP in ambulant patients.
منابع مشابه
Basic principles of the intraaortic balloon pump and mechanisms affecting its performance.
The intraaortic balloon pump (IABP) is the single most effective and widely used device for temporary mechanical assistance of the failing heart. Although the principles underlying IABP function are simple, various biologic factors often determine its performance in a particularly complicated way. We briefly describe the basic disciplines of counterpulsation by IABP and the induced hemodynamic ...
متن کامل2-D ECHO IN EXPERIMENTAL CORONARY STENOSISIPandian and Kerber
(with carbon dioxide) in the aortaa mechanical assistance to the failing ciruclation. Am Heart J 63: 669, 1962 24. Braunwald E, Covell JW, Moroko PR, Ross J: Effects of drugs and of counterpulsation on myocardial oxygen consumption: observations on the ischemic heart. Circulation 40 (suppl IV): IV-220, 1969 25. Powell WJ, Daggett WM, Magro AE, Bianco JA, Buckley MJ, Sanders CA, Kantrowitz AR, A...
متن کاملParaplegia associated with intraaortic balloon pump counterpulsation.
Two patients developed paraplegia associated with the use of the intraaortic balloon pump. In one patient, transient spinal ischemic episodes ceased after removal of the intraaortic balloon and the second patient apparently sustained spinal cord infarction. Possible etiologic mechanisms include vascular occlusion due to balloon position, arterial spasm, thromboembolic phenomena, hypotension, hy...
متن کاملIntraaortic balloon counterpulsation in a community hospital.
Our experience with intraaortic balloon counterpulsation in 41 patients documents the feasibility of a coordinated aggressive therapeutic approach in patients with potentially fatal complications of coronary artery disease. The use of intraaortic balloon pump in a non-cardiac surgical center has allowed hemodynamic support in the critically ill, safety in angiography, appropriate selection of p...
متن کاملProphylactic intraaortic balloon counterpulsation in high-risk cardiac surgery: a survey of opinion and current practice
INTRODUCTION Patients undergoing cardiac surgery increasingly have greater comorbidities and subsequently are at higher risk of adverse postoperative outcomes. Despite some evidence suggests that prophylactic intraaortic balloon counterpulsation reduces mortality in selected high-risk patients, its use remains low. The aim of this study was to investigate reported management strategies of high-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 114 1 Suppl شماره
صفحات -
تاریخ انتشار 2006