Analytical reconstruction of 4D dynamic cardiac SPECT with noise-reduction and non-uniform attenuation compensation.
نویسندگان
چکیده
BACKGROUND: This study focuses on quantitative reconstruction of dynamic cardiac SPECT. MATERIAL AND METHODS: The Karhunen-Loeve (KL) transform is first applied to gated frames or sinogram data to de-correlate the dynamic information along the time direction. Then the Poisson noise is treated by a penalized weighted least-squares minimization, followed by an analytical inversion of the treated sinograms with attenuation compensation via the Novikov formula. The reconstruction is completed by inverse KL transform. RESULTS: Dynamic or gated cardiac sinograms were simulated from the NCAT phantom mimicking the human torso, and their reconstructions by the presented method showed significant improvement over the conventional methods of frame-by-frame reconstruction. CONCLUSION: This analytical reconstruction of dynamic SPECT is consistent and efficient with a good potential for practical use.
منابع مشابه
Fast Analytical Reconstruction of Gated Cardiac SPECT with Non-Uniform Attenuation Compensation
Conventionally, the inverse problem of gated cardiac SPECT is solved by reconstructing the images frame-by-frame, ignoring the inter-frame correlation along the time dimension. To compensate for the non-uniform attenuation for quantitative cardiac imaging, iterative image reconstruction has been a choice which could utilize an a priori constraint on the inter-frame correlation for a penalized m...
متن کاملSpatially-Adaptive Analytical Reconstruction for Gated Quantitative SPECT in KL Domain
Gated cardiac SPECT imaging has been widely used in the evaluation of cardiac functions. The acquired fourdimensional (4D) sinogram data have both inter-frame correlation among the time sequence and intra-frame correlation within each 3D frame. The unique features of Karhune-Loève (KL) transform for de-correlating the data sequence for noise reduction, feature extraction, etc, have been well re...
متن کاملA New Approach for Scatter Removal and Attenuation Compensation from SPECT/CT Images
Objective(s): In SPECT, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. Many techniques for attenuation and scatter correction have been proposed. An acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. Here, we propose new Maximum Likelihood Expectation Maximiz...
متن کاملAdvances in 4D Gated Cardiac PET Imaging for Image Quality Improvement and Cardiac Motion and Contractility Estimation
Quantitative four-dimensional (4D) image reconstruction methods with respiratory and cardiac motion compensation are an active area of research in ECT imaging, including SPECT and PET. They are the extensions of three-dimensional (3D) statistical image reconstruction methods with iterative algorithms that incorporate accurate models of the imaging process and provide significant improvement in ...
متن کاملCollimator-detector response compensation in molecular SPECT reconstruction using STIR framework
Introduction:It is well-recognized that collimator-detector response (CDR) is the main image blurring factor in SPECT. In this research, we compensated the images for CDR in molecular SPECT by using STIR reconstruction framework. Methods: To assess resolution recovery capability of the STIR, a phantom containing five point sources along with a micro Derenzo p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
دوره 571 شماره
صفحات -
تاریخ انتشار 2007