Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device

نویسندگان

  • Naoki Tojo
  • Atsushi Hayashi
  • Akio Miyakoshi
چکیده

PURPOSE To report a case of corneal decompensation due to the Ex-PRESS(®) mini glaucoma shunt device (Ex-PRESS). PATIENT AND METHODS A 75-year-old man had pseudoexfoliation glaucoma in his right eye. He underwent filtration surgery with Ex-PRESS. His intraocular pressure was 7 mmHg after 9 months. RESULTS We observed partial decompensation of the corneal endothelium adjacent to the filtering bleb. Specular microscopy revealed a marked decrease in the endothelial cell density at the center of the cornea. CONCLUSION Anterior segment optical coherence tomography is very useful for evaluating corneal edema and the position of Ex-PRESS. It is important to follow up with an examination of the corneal endothelial cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Surgical Treatment of Neovascular Glaucoma with Ex-PRESS P-50 Miniature Glaucoma Shunt

Surgical treatment for neovascular glaucoma has evolved from cyclodestructive procedures to full-thickness filtration surgery, to trabeculectomy with antifibrosis drugs and glaucoma drainage implant surgery. The choice of a surgical approach may be influenced by several factors, including the stage of the disease. Many surgeons favor drainage implants when the disease is more advanced or when s...

متن کامل

Changes of corneal endothelial cell density after EX-PRESS® Glaucoma shunt implantation: 2-year follow-up study

Purpose: To evaluate effects of the EX-PRESS® glaucoma filtering device on the corneal endothelial cell density (ECD) in eyes with open angle glaucoma (OAG). Designs: A prospective, non-comparative study. Methods: We prospectively evaluated the changes in the ECD, hexagonality, and coefficient of variation (CV) in 20 eyes of 19 patients who had an implantation of the EX-PRESS®. The type of glau...

متن کامل

Trabeculectomy Versus EX-PRESS Shunt Versus Ahmed Valve Implant: Short-term Effects on Corneal Endothelial Cells.

PURPOSE To evaluate short-term changes in corneal endothelial cells after trabeculectomy, EX-PRESS device implantation, and Ahmed valve implantation for the treatment of primary open-angle glaucoma. DESIGN Prospective, interventional, comparative case series with contralateral eye control study. METHODS We prospectively evaluated the changes in number, density, and shape of the corneal endo...

متن کامل

A comparison of the Ex-PRESS™ mini glaucoma shunt with standard trabeculectomy in the surgical treatment of glaucoma.

BACKGROUND AND OBJECTIVE To compare the success and complication rates of patients with glaucoma who had an Ex-PRESS mini glaucoma shunt device implantation (Optonol, Ltd., Neve Ilan, Israel) to those who had conventional trabeculectomy. PATIENTS AND METHODS The records of 76 eyes of 69 consecutive subjects who had Ex-PRESS implants and 77 eyes of 65 consecutive controls who had trabeculectom...

متن کامل

Clinical experience with Ex-press Mini Glaucoma Shunt implantation.

In this prospective study we wanted to report our experience and to evaluate the efficacy and safety of Ex-press Mini-Glaucoma Shunt implantation under a superficial scleral flap, as a newly and improved surgical technology in a treatment of POAG (Primary open-angle glaucoma) and refractory glaucoma. 44 eyes (35 patients) underwent an implantation of Ex-Press Mini Glaucoma Shunt. We had 21 pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015