Comparison of 3T MR scanners in regional cartilage-thickness analysis in osteoarthritis: a cross-sectional multicenter, multivendor study

نویسندگان

  • Sharon Balamoody
  • Tomos G Williams
  • John C Waterton
  • Michael Bowes
  • Richard Hodgson
  • Chris J Taylor
  • Charles E Hutchinson
چکیده

INTRODUCTION Cartilage thickness from MR images has been identified as a possible biomarker in knee osteoarthritis (OA) research. The ability to acquire MR data at multiple centers by using different vendors' scanners would facilitate patient recruitment and shorten the duration of OA trials. Several vendors manufacture 3T MR scanners, including Siemens, Philips Medical Systems, and GE Healthcare. This study investigates whether quantitative MR assessments of cartilage morphology are comparable between scanners of three different vendors. METHODS Twelve subjects with symptoms of knee OA and one or more risk factors had their symptomatic knee scanned on each of the three vendor's scanners located in three sites in the UK: Manchester (Philips), York (GE), and Liverpool (Siemens). The NIH OAI study protocol was used for the Siemens scanner, and equivalent protocols were developed for the Philips and GE scanners with vendors' advice. Cartilage was segmented manually from sagittal 3D images. By using recently described techniques for Anatomically Corresponded Regional Analysis of Cartilage (ACRAC), a statistical model was used anatomically to align all the images and to produce detailed maps of mean differences in cartilage-thickness measures between scanners. Measures of cartilage mean thickness were computed in anatomically equivalent regions for each subject and scanner image. RESULTS The ranges of mean cartilage-thickness measures for this cohort were similar for all regions and across all scanners. Philips intrascanner root-mean-square coefficients of variation were low in the range from 2.6% to 4.6%. No significant differences were found for thickness measures of the weight-bearing femorotibial regions from the Philips and Siemens images except for the central medial femur compartment (P = 0.04). Compared with the other two scanners, the GE scanner provided consistently lower mean thickness measures in the central femoral regions (mean difference, -0.16 mm) and higher measures in the tibial compartments (mean difference, +0.19 mm). CONCLUSIONS The OAI knee-imaging protocol, developed on the Siemens platform, can be applied to research and trials by using other vendors' 3T scanners giving comparable morphologic results. Accurate sequence optimization, differences in image postprocessing, and extremity coil type are critical factors for interscanner precision of quantitative analysis of cartilage morphology. It is still recommended that longitudinal observations on individuals should be performed on the same scanner and that assessment of intra- and interscanner precision errors is undertaken before commencement of the main study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Osteoarthritis Initiative (OAI) magnetic resonance imaging quality assurance update.

OBJECTIVE Longitudinal quantitative evaluation of cartilage disease requires reproducible measurements over time. We report 8 years of quality assurance (QA) metrics for quantitative magnetic resonance (MR) knee analyses from the Osteoarthritis Initiative (OAI) and show the impact of MR system, phantom, and acquisition protocol changes. METHOD Key 3T MR QA metrics, including signal-to-noise, ...

متن کامل

Double Echo Steady State (DESS) Magnetic Resonance Imaging of Knee Articular Cartilage at 3 Tesla – a Pilot Study for the Osteoarthritis Initiative

Objective: Quantitative magnetic resonance imaging (qMRI) may provide valuable measures of cartilage morphology in osteoarthritis (OA) but has been confined to sequences with relatively long acquisition times at 1.5 Tesla (T). Here we test the accuracy and precision of knee cartilage qMRI with a fast double echo steady state (DESS) sequence with water excitation (we) at 3T. Methods: As a pilot ...

متن کامل

Evaluation of clinical symptoms and sonographic characteristics of femoral trochlear cartilage in primary knee osteoarthritis

Objective: This study was designed to evaluate the clinical symptoms and sonographic characteristics of femoral trochlear cartilage in patients with knee joint osteoarthritis (OA). Methods: This cross-sectional study was conducted on 94 patients with painful primary knee OA according to the American College of Rheumatology criteria with a visual analog scale pain score of 30 mm or more. Clinica...

متن کامل

Bone marrow edema-like lesions and cartilage degeneration in osteoarthritis using 3T MR T1rho quantification: longitudinal assessment

INTRODUCTION Bone marrow edema-like lesions (BMEL) are defined as areas of high signal intensity in T2-weighted, fat-saturated magnetic resonance (MR) images or in short inversion time inversion-recovery images. These lesions are present in knee osteoarthritis (OA) and acute knee injuries. While MR findings of BMEL are common, our knowledge concerning their natural history and significance is l...

متن کامل

Reproducibility of the whole-brain N-acetylaspartate level across institutions, MR scanners, and field strengths.

BACKGROUND AND PURPOSE Radiologic markers in multicenter trials are often confounded by different instrumentation used. Our goal was to estimate the variance of the global concentration of the neuronal cell marker N-acetylaspartate (NAA) among research centers using MR imaging scanners of different models, from different manufacturers, and of different magnetic field strength. MATERIALS AND M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2010