A Piece of Broken Metal from Intubation Stylet Retained in Tracheobronchial Tree: A Case Report
نویسندگان
چکیده
Intubation stylets are still being used in many medical centers for difficult intubations. Although very rare, it may break inside the trachea during endotracheal intubation despite routine pre-assessments by anesthesiologists and may surprisingly move deep into the tracheobronchial tree. In this case report, we describe a rare complication after stylet or guide-wire intubation in a patient in whom, a broken piece of metal guide remained in his tracheobronchial tree for 3 days. A 62 year-old man was admitted to our hospital with the chief complaint of functional class 3 dyspnea. The patient was a known case of chronic obstructive pulmonary disease (COPD) from 3 years ago with a history of heavy smoking (40 p/y) and oral opioid usage. We report a case with an unrecognized broken piece of stylet in his trachea and left main bronchus, which was later detected by CT scan and extracted before causing pressure rise symptoms in the airway. Despite precise evaluation before use, signs of breakage in the stylet may be missed and consequently, it may break inside the trachea and result in serious complications. It is strongly recommended that the anesthesiologists pay attention to the sounds and movements of the instruments. This article also briefly reviews the most serious reported complications due to stylet breakage.
منابع مشابه
A rare cause of endotracheal tube obstruction: a broken stylet going unnoticed--a case report.
In anesthesia practice, stylet is used as an aid in difficult tracheal (ET) intubation. Disposable plastic covered or plastic bougies are recommended but in developing countries, the metal stylets are still in use. Shearing of part of stylet has been reported in past but all incidents were detected immediately. We report a case of tracheal tube blockade due to a broken stylet tip which initiall...
متن کاملA Near Miss: Case Report and Literature Review
We report a 28-week gestation premature infant with rare complication of endotracheal intubation. A piece from the plastic sheath of the stylet was retrieved inside the endotracheal tube after extubation.
متن کاملPartial Obstruction of the Endotracheal Tube by the Plastic Coating Sheared from a Stylet.
A preterm with gestational age of 24 weeks was intubated at day of life 16. The intubation was done in a routine manner with the use of a stylet. It took a significant effort from the clinician to pull the stylet out after intubation. After intubation the respiratory status of the neonate deteriorated requiring significantly greater support. When ventilating and oxygenating the infant was getti...
متن کاملThe Clarus Video System stylet for awake intubation in a very difficult urgent intubation.
Awake fibreoptic intubation (AFI) is a standard method of airway management in a case of anticipated difficult intubation. It is usually performed using flexible fibroscopes. In this report, we describe the case of a 42 year-old female patient who suffered from congenital disease producing severe deformation of the head, face, neck and chest. In this case, the AFI procedure was performed succes...
متن کاملCase report of a piece of dishwashing steel wool in a child’s pharynx
Objective: Foreign body swallowing is a common pediatric problem. A foreign body in the pharynx is a medical emergency that requires urgent intervention. Evaluation and treatment of pharyngeal foreign bodies is much more difficult in children than in adults and sometimes requires hospitalization and removal of the foreign bodies under general anesthesia due to children’s lack of cooperation. Fi...
متن کامل