The effect of step-stretch parameters on capillary breakup extensional rheology (CaBER) measurements

نویسندگان

  • Erik Miller
  • Christian Clasen
  • Jonathan P. Rothstein
چکیده

Extensional rheometry has only recently been developed into a commercially available tool with the introduction of the capillary breakup extensional rheometer (CaBER). CaBER is currently being used to measure the transient extensional viscosity evolution of mid to low-viscosity viscoelastic fluids. The elegance of capillary breakup extensional experiments lies in the simplicity of the procedure. An initial step-stretch is applied to generate a fluid filament. What follows is a self-driven uniaxial extensional flow in which surface tension is balanced by the extensional stresses resulting from the capillary thinning of the liquid bridge. In this paper, we describe the results from a series of experiments in which the step-stretch parameters of final length, and the extension rate of the stretch were varied and their effects on the measured extensional viscosity and extensional relaxation time were recorded. To focus on the parameter effects, well-characterized surfactant wormlike micelle solutions, polymer solutions, and immiscible polymer blends were used to include a range of characteristic relaxation times and morphologies. Our experimental results demonstrate a strong dependence of extensional rheology on step-stretch conditions for both wormlike micelle solutions and immiscible polymer blends. Both the extensional viscosity and extensional relaxation time of the wormlike micelle E. Miller · J. P. Rothstein (B) Department of Mechanical and Industrial Engineering, University of Massachusetts, Amherst, MA 01003, USA e-mail: [email protected] C. Clasen Department of Chemical Engineering, Katholieke Universiteit Leuven, 3001 Leuven, Belgium solutions were found to decrease with increasing extension rate and strain of the step-stretch. For the case of the immiscible polymer blends, fast step-stretches were found to result in droplet deformation and an overshoot in the extensional viscosity which increased with increasing strain rates. Conversely, the polymer solutions tested were found to be insensitive to step-stretch parameters. In addition, numerical simulations were performed using the appropriate constitutive models to assist in both the interpretation of the CaBER results and the optimization of the experimental protocol. From our results, it is clear that any rheological results obtained using the CaBER technique must be properly considered in the context of the stretch parameters and the effects that preconditioning has on viscoelastic fluids.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extensional flow of blood analog solutions in microfluidic devices.

In this study, we show the importance of extensional rheology, in addition to the shear rheology, in the choice of blood analog solutions intended to be used in vitro for mimicking the microcirculatory system. For this purpose, we compare the flow of a Newtonian fluid and two well-established viscoelastic blood analog polymer solutions through microfluidic channels containing both hyperbolic an...

متن کامل

Is there a Relationship between the Elongational Viscosity and the First Normal Stress Difference in Polymer Solutions?

We investigate a variety of different polymer solutions in shear and elongational flow. The shear flow is created in the cone-plate-geometry of a commercial rheometer. We use capillary thinning of a filament that is formed by a polymer solution in the Capillary Breakup Extensional Rheometer (CaBER) as an elongational flow. We compare the relaxation time and the elongational viscosity measured i...

متن کامل

A miniature capillary breakup extensional rheometer by electrostatically assisted generation of liquid filaments.

A micromachined chip capable of generating liquid microfilaments has been developed for a miniature version of the Capillary Breakup Extensional Rheometer (CaBER®). The proposed system is exceptionally simple and compact because liquid samples are actuated by voltages administered on-chip, which therefore requires only electrical connections (rather than a linear motor, an integral part of the ...

متن کامل

Filament stretching and capillary breakup extensional rheometry measurements of viscoelastic wormlike micelle solutions

filament stretching extensional rheometer and capillary breakup extensional rheometer are used o measure the extensional rheology of a series of wormlike micelle solutions experiencing a niaxial elongational flow. The experiments are performed using a series of wormlike micelle olutions of both cetylpyridinium chloride and sodium salicylate NaSal in an aqueous sodium hloride solution and cetylt...

متن کامل

PRO O F CO PY 001704 JO R Filament stretching and capillary breakup extensional rheometry measurements of viscoelastic wormlike micelle solutions

A filament stretching extensional rheometer and capillary breakup extensional rheometer are used to measure the extensional rheology of a series of wormlike micelle solutions experiencing a uniaxial elongational flow. The experiments are performed using a series of wormlike micelle solutions of both cetylpyridinium chloride and sodium salicylate NaSal in an aqueous sodium chloride solution and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009