An instrument for monitoring stump oedema and shrinkage in amputees.

نویسندگان

  • G R Fernie
  • P J Holliday
  • R J Lobb
چکیده

A new system for measuring the cross-sectional area profiles of amputation stumps and whole limbs has been designed at the Amputee Research Centre. The instrument consists of a cylindrical tank supported on an elevator. The tank is raised to the height of the amputation stump and filled with water. A graph of the cross-sectional area profile of the amputation stump is generated by a mini-computer as the elevator descends. The cross-sectional area (A) is calculated from the expression: formula: (see text) where Hw = height of water in the tank He = height of the elevator Ac = a constant, related to the size of the measuring tank. This paper describes the instrument, which may find application in many other areas where there is a need to study shape.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Approach to Stump Shrinkage for Above-knee Amputees

the part of the writer with results obtabed from presently employed techniques used to accomplish a preformed stump for incorporation in a permanent socket. This technique has been used only on a small number of geriatric amputees where amputations were performed because of circulatory complications. The initial evaluation of this method produced the following observations: the stump was less s...

متن کامل

Temporary prosthetic fitting for below-knee amputation.

The problems encountered in fitting and using the permanent below-knee prosthesis in developing countries are the high price of the prosthesis, inadequate fitting and lack of proper rehabilitation. In Turkey, the preferred treatment of the stump post-operatively is by the soft dressing method with bandaging for maturation and shrinkage. Generally, the application of the permanent prosthesis is ...

متن کامل

Use of temporary plaster of plastic pylons preparatory to fitting a permanent above-knee or below-knee prosthesis.

Temporary or preparatory prostheses for use by lower-extremity amputees have been mentioned frequently and used occasionally for many years (1, 2, 3, 4, 5), but they have not been adopted readily in the United States. Many reasons have been given why preliminary fitting has not been done and these have included: 1. stump damage because of malfitting plaster or other temporary socket, 2. rapid s...

متن کامل

A device for tracing contour of amputation stump and extremities: the contour-tracer.

There is a definite need to determine the exact size and shape of a stump or extremity in order to ascertain quickly any changes in contour and size, and at the same time to have tracings of the periodic reevaluations. A number of methods are presently used, such as the water displacement method, measuring the circumference of the stump or extremity at a number of points, and photography. None ...

متن کامل

Determinants of skin problems of the stump in lower-limb amputees.

OBJECTIVE To identify determinants of skin problems in lower-limb amputees. DESIGN Survey, using a questionnaire. SETTING Not applicable. PARTICIPANTS Lower-limb amputees (N=2039) who either obtained their prosthesis through the Orthopedische Instrument Makerij (a group of orthopedic workshops in the Netherlands) or were a member of the (Dutch) National Society of Amputees (Landelijke Ver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 2 2  شماره 

صفحات  -

تاریخ انتشار 1978