Osmotic flows across the blood-joint barrier.
نویسندگان
چکیده
The effective osmotic pressure across the blood-joint barrier is a key factor controlling synovial fluid volume and joint effusions. The effect of plasma colloid osmotic pressure (COP) on trans-synovial flow was studied directly in rabbit knees expanded by intra-articular fluid infusion. The synovial microcirculation was perfused with blood of varying COP. Absorption of fluid from the joint cavity was a linear function of COP; but albumin COP was only 78% effective across the blood-joint interface. Hyperosmolar solutions of small solutes (e.g., glucose) generated transient osmotic flows across the blood-joint barrier, but far less effectively than albumin. The hydraulic permeability of synovium increased at pathological intra-articular pressures--a phenomenon of potential importance to effusion kinetics.
منابع مشابه
Investigating Fluid Mixing in Electro-Osmotic Flow Through Passive Micro-Mixers Having Square and Triangle Barriers
Objective: In this article, a numerical study is conducted on mixing of two fluids in the liquid phase with two different concentrations of a chemical species in the electro-osmotic flow. Methods: The base liquid is an electrolyte which flows in a two-dimensional micro-channel having electrically charged walls. Lorentz electric force, which is used as stimulating flow factor, is created by appl...
متن کاملInvestigating Fluid Mixing in Electro-Osmotic Flow Through Passive Micro-Mixers Having Square and Triangle Barriers
Objective: In this article, a numerical study is conducted on mixing of two fluids in the liquid phase with two different concentrations of a chemical species in the electro-osmotic flow. Methods: The base liquid is an electrolyte which flows in a two-dimensional micro-channel having electrically charged walls. Lorentz electric force, which is used as stimulating flow factor, is created by appl...
متن کاملDetermination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays
Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...
متن کاملOrigins and consequences of hyperosmolar stress in retinal pigmented epithelial cells
The retinal pigmented epithelium (RPE) is composed of retinal pigmented epithelial cells joined by tight junctions and represents the outer blood-retinal barrier (BRB). The inner BRB is made of endothelial cells joined by tight junctions and glial extensions surrounding all the retinal blood vessels. One of the functions of the RPE is to maintain an osmotic transepithelial gradient created by i...
متن کاملPharmacology and neurotoxicity of cis-diamminedichloroplatinum, bleomycin, 5-fluorouracil, and cyclophosphamide administration following osmotic blood-brain barrier modification.
cis-Platinum, bleomycin, 5-fluorouracil, and cyclophosphamide were administered to rodent and canine models of osmotic blood-brain barrier modification to evaluate the relationship between tissue drug concentration in brain and the physiological and neuropathological effects of the drug. The toxicity studies were carried out in the canine, and the pharmacological studies were carried out in the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of the rheumatic diseases
دوره 46 7 شماره
صفحات -
تاریخ انتشار 1987