A clinical description of Ocular Response Analyzer measurements.

نویسندگان

  • William Lau
  • David Pye
چکیده

PURPOSE To examine the interrelationships among the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY), Goldmann applanation tonometer (GAT), and corneal geometry measurements in a young, healthy sample. METHODS Central corneal radius, ORA, GAT, and central corneal thickness (CCT) measurements were taken in 99 subjects (age, 21 ± 2 years) who were free of ocular and systemic disease. RESULTS The mean ± SD corneal hysteresis (CH) and corneal resistance factor (CRF) were 10.4 ± 1.2 and 10.1 ± 1.5 mm Hg, respectively. The Bland-Altman 95% limits of agreement of ORA Goldmann-correlated IOP (ORAg) and ORA corneal-compensated (ORAcc) IOP with reference to GAT were -4.5 to +6.0 and -4.1 to +6.8 mm Hg, respectively. The full equations used by the ORA to calculate ORAcc and CRF were reconstructed. The statistically significant effect of CCT on GAT became redundant if CRF was included in a multivariate regression analysis. Both CH and CRF were associated with CCT (R(2) = 0.252 and 0.290, respectively). CONCLUSIONS Sample CH and CRF were consistent with those reported in the literature. ORAg and ORAcc agreed poorly with GAT. CRF appears to be at least a partial description of corneal rigidity. The ocular determinants of CH are unclear.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasonographic findings of some ocular structures in Caspian miniature horse

Ultrasonography is a relatively easy, safe and non-invasive examination method which can be used in diagnosis of ocular disorders as complementary to routine ophthalmic examinations. As there has been no collated study undertaken on the normal measurements of ocular structures in Caspian miniature horse, obtaining these measurements could be a benchmark to diagnose some of the diseases and eye ...

متن کامل

Ocular Ultrasonographic Features in Iranian Native Donkey

Objective- The aim of this study was to evaluate ultrasonographic appearance of the normal eye and obtaining reference values of ocular structures in Iranian native donkey. Design- Experimental study. Animals- Five Iranian native donkeys. Procedures- After preparation of the animals, ocular structures were ima...

متن کامل

Measurement and analysis of the air pressure curve on the rigid lenses by use of ocular response analyzer.

PURPOSE Pressure curves obtained from Ocular Response Analyzer (ORA) differ for the same patient in form and height. In some cases measurements on the subject show significant differences between recorded pressure curves. The purpose of the paper is to examine if the differences result from the corneal properties or from the device operation. METHODS Examination of air pressure curves was car...

متن کامل

Determination of the frequency and response to treatment of ocular lesions in children with various types of intrauterine infections (cytomegalovirus and toxoplasmosis): brief report

Background: Intrauterine infections (TORCH) lead to the involvement of various organs of the body of the fetus, including the eye. The aim of this study was to determine the frequency and clinical response of eye lesions to specific drugs, in infants with confirmed TORCH induced ocular lesions. Methods: This historical cohort study from 2011 to 2017, had done in Pediatrics and Ophthalmology De...

متن کامل

Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer.

PURPOSE The Ocular Response Analyzer (ORA) proposes to measure corneal biomechanical properties in vivo by monitoring and analyzing the corneal behavior when this structure is submitted to a force induced by an air jet. The purpose of this study was to evaluate the relationship between corneal biomechanical properties and corneal-compensated intraocular pressure (IOPCC) measurements as obtained...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 2011