The elastic constant of tissue in the body estimated from computerized tomography and ultrasonography--theoretical analysis.
نویسندگان
چکیده
This paper describes a method for calculating the elastic constant of tissue. Length measurements obtained from Ultrasonograms (US) are different from the results obtained from Computerized Tomograms (CT) when the velocity of sound is compared to standardized water measurements. The density of tissue PI can be approximated by the equation. p, = 1N</N,;•. where N, and N". are the CTvalues of tissue and air respectively. The elastic constant (bulk modulus) K,. sound velocity Y, and density PI are related through the following equation, Y= (K./ PI)O.,. The elastic constant K, is then calculated by, K, = Kw (L,j L,)2. (I N</ N,;.), where Kw is the bulk modulus of water, and L, and L, are the measured distances from CT and US images respectively.
منابع مشابه
Comparison between Needle Biopsy under Guide of Conventional Computerized Tomography (CCT) and Fluoroscopic Computerized Tomography (FCT) in Abdominal, Mediastinal, Lung, Pelvic, Bone, and Liver Masses
Background and Objective: Computerized tomography and fluoroscopic computerized tomography are amongst the methods used for guiding needle biopsy processes; however, fluoroscopic computerized tomography demonstrates the images during the process of biopsy. This study aims to compare and contrast the success of biopsy under guide...
متن کاملO-1: Suitability of Epididymal and Testicular Ultrasonography and Computerized Image Analysis for Assessment of Current and Future Semen Quality in The Ram
Background: Breeding soundness evaluation (BSE) is the primary assessment for determining reproductive potential of male animals. This method, however, cannot be used to evaluate semen frequently or to predict future semen quality. Computerized analysis of ultrasonographic images provides information on histophysiological changes in male reproductive organs.We hypothesized that: 1. semen parame...
متن کاملValidation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملAnalysis of Nonlinear Vibrations for Multi-walled Carbon Nanotubes Embedded in an Elastic Medium
Nonlinear free vibration analysis of double-walled carbon nanotubes (DWCNTs) embedded in an elastic medium is studied in this paper based on classical (local) Euler-Bernoulli beam theory. Using the averaging method, the nonlinear free vibration responses of DWCNTs are obtained. The result is compared with the obtained results from the harmonic balance method for single-walled carbon nanotubes (...
متن کاملCorrelation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)
Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nagoya journal of medical science
دوره 44 1-2 شماره
صفحات -
تاریخ انتشار 1981