Evaluation of ultrasound lung comets by hand-held echocardiography

نویسندگان

  • G Bedetti
  • L Gargani
  • A Corbisiero
  • F Frassi
  • E Poggianti
  • G Mottola
چکیده

BACKGROUND Ultrasound lung comets (ULCs) are a clinically useful sign of extravascular lung water. They require very limited technology (2 D-echo), and a short learning curve. The aim of the present study is to compare ULCs information obtained by experienced echocardiologists using a full feature echocardiographic platform and by inexperienced sonographers using a hand-held echocardiography system. METHODS 20 consecutive in-hospital patients underwent, within 15' and in random order, 2 ultrasound examinations for ULCs by 2 observers with different specific expertise and different technology: 1) "high-tech veteran": ULCs assessment with full feature echocardiographic platform (HP Sonos 7500 Philips Medical Systems, Andover, MA, USA) by a trained echocardiologist, with > or =2 years expertise in ULCs assessment and accredited by the European Association of Echocardiography; 2) and a "low-tech beginner": ULCs assessment with hand-held echocardiography (Optigo; Philips, Andover, MA) by an echocardiographer with very limited (30') dedicated training on ULCs assessment. In each patient, ULC score was obtained by summing the number of comets from each of the scanning spaces in the anterior right and left hemithorax, from the second to the fifth intercostal space. RESULTS There was a significant, tight correlation (r = .958, p < 0.001) between the 2 observations in the same patient by "high-tech veteran" and "low-tech beginner". CONCLUSION ULCs are equally reliable in the hands of highly experienced echocardiologists using full feature echocardiographic platforms and in the hands of absolute beginners with miniaturized, compact, and battery-equipped echocardiographic systems. From the technological and expertise viewpoint, ULCs are the "kindergarten" of echocardiography, ideally suited for bedside evaluation of patients with both known or suspected heart failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The best of 2005 in echocardiography back from EuroEcho 9 – Florence, Italy

The ninth edition of the congress of the European Association of Echocardiography (EAE) (former working group of Echocardiography) held in Florence has just finished with a great success of participant attendance (2.842) and abstract submissions. Hot topics at EuroEcho 9 were: 1--live 3-dimensional echocardiography and surgical decision making; in pediatric cardiology; in resynchronization ther...

متن کامل

The use of small personal ultrasound devices by internists without formal training in echocardiography.

AIMS Hand-held ultrasound devices will probably be used for bedside cardiac diagnoses by internists without formal training in echocardiography. We compared the accuracy of hand-held ultrasound devices studies performed by expert echocardiographers vs internal medicine residents with brief training in echocardiography. METHODS AND RESULTS Three internal medicine residents participated in an o...

متن کامل

Hand-held echocardiography: added value in clinical cardiological assessment

BACKGROUND The ultrasonic industry has recently produced echocardiographic Hand Held Devices (miniaturized, compact and battery-equipped echocardiographic systems). Their potential usefulness has been successfully assessed in a wide range of clinical conditions. The aim of the study was to verify if the routine use of a basic model of echocardiographic Hand Held Device (HHD) could be an importa...

متن کامل

Role of echocardiography in diagnosis and risk stratification in heart failure with left ventricular systolic dysfunction

Heart failure (HF) is a complex clinical syndrome that can result from any structural or functional cardiac disorder that impairs the ability of the ventricle to fill with or eject blood. Echocardiography represents the "gold standard" in the assessment of LV systolic dysfunction and in the recognition of systolic heart failure, since dilatation of the LV results in alteration of intracardiac g...

متن کامل

Reliability of cardiac dimensions and valvular regurgitation assessment by sonographers using hand-carried ultrasound devices.

AIM We sought to assess the reliability of some basic echocardiographic data obtained by trained sonographers using a hand-held ultrasound device. METHODS One hundred and twelve consecutive patients (mean age 61, 64 males) referred for in-hospital or ambulatory routine echocardiography were considered. All patients underwent two-dimensional and colour Doppler examination performed by a traine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiovascular Ultrasound

دوره 4  شماره 

صفحات  -