Development, validation and application of an HPLC-MS/MS method for the determination of fentanyl and nor-fentanyl in human plasma and saliva.
نویسندگان
چکیده
Monitoring fentanyl concentration in saliva and plasma may be useful in pharmacokinetic/pharmacodynamic studies. Salivettes(®) have been used widely for collecting saliva samples. However due to its lipophilicity, fentanyl adsorbs to the cotton dental bud (CDB) used in this device. Furthermore, due to dry mouth being a common adverse effect seen in patients treated with opioids, obtaining enough saliva for analysis is often a challenge. Hence, a simple simultaneous method to quantify fentanyl and its metabolite in both human plasma and saliva was developed and validated. A novel extraction method was also developed and validated to recover fentanyl in saliva directly from the CDB. This extraction method utilises acetonitrile to recover the fentanyl directly from the CDB rather than recovery by centrifugation, which is not always possible. Reverse phase chromatographic separation was performed on a Shimadzu LC 20A HPLC system using gradient elution. The electrospray ion source (ESI) was operated in positive ion mode using an Applied Biosystems API 3200 LC/MS/MS as detector. Deuterated fentanyl (D5) and nor-fentanyl (D5) were used as internal standards (IS). The retention times for fentanyl and nor-fentanyl were 3.70 min and 3.20 min respectively. The lower limit of quantitation (LLOQ) was determined to be 0.030 μg/L in plasma and 0.045 in saliva for fentanyl and nor-fentanyl. Acceptable linearity for fentanyl and nor-fentanyl in both plasma and saliva was demonstrated from 0.02 to 10 μg/L (R(2) 0.9988-0.9994). Accuracy for fentanyl and nor-fentanyl in both plasma and saliva samples was between 96% and 108%. Total imprecision expressed as the co-efficient of variation was between 1.0 and 15.5% for both analytes in both matrices. The validated method was applied successfully in 11 paired plasma and saliva samples obtained from patients with cancer pain receiving transdermal fentanyl (Duragesic(®)) at doses from 25 μg to 100 μg.
منابع مشابه
Quantitative determination of fentanyl in newborn pig plasma and cerebrospinal fluid samples by HPLC-MS/MS.
In this study, a selective and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method requiring low sample volume (≤100 μL) was developed and validated for the quantitative determination of the opioid drug fentanyl in plasma and cerebrospinal fluid (CSF). A protein precipitation extraction with acetonitrile was used for plasma samples whereas CSF samples w...
متن کاملDevelopment and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...
متن کاملDevelopment and Application of a Validated Liquid Chromatography-Mass Spectrometry Method for the Determination of Dexchlorpheniramine Maleate in Human Plasma
A convenient liquid chromatographic-single Quadrupole mass spectrometric (LC-MS) method was developed and validated for dexchlorpheniramine maleate (INN name: chlorphenamine) determination in human plasma. The need for just a single liquid-liquid extraction with ethyl acetate and being highly sensitive were the advantages of this method. The linearity was also excellent over the range of 1...
متن کاملMethod validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.
Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...
متن کاملDevelopment and Validation of an HPLC Method for Determination of Amifostine and/or Its Metabolite (WR-1065) In Human Plasma Using OPA Derivatization and UV Detection
A rapid, sensitive and reproducible HPLC method was developed and validatedfor the analysis of amifostine (AMF) and/or its metabolite, WR-1065 inhuman plasma. The method involves the alkylation of free sulfydryl group with iodoacetic acid followed by derivatization of the drug and its metabolite witho-phthaldialdehyde (OPA) andUVdetection at 340 nm. The derivatized AMF and WR-1065 were eluted i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
دوره 960 شماره
صفحات -