Arthroscopic-assisted removal of proximal tibia locking plates
نویسندگان
چکیده
We present a new technique to remove plates from the proximal tibia arthroscopic-assisted with all advantages of the minimally invasive surgery and the possibility to treat concomitant intraarticular pathologies. The initial results (n = 7) are promising with an increase of the Lysholm score in all cases studied [preop. median 78 (range 32-100), postop. median 89 (range 60-100)]. In conclusion, arthroscopic-assisted hardware removal at the proximal tibia is feasible and may provide patients with all the benefits of minimal-invasive hardware removal. The described technique can be recommended for all surgeons familiar with arthroscopic surgery.
منابع مشابه
The arthroscopic-assisted removal of a distal femoral condylar locking plate--a case report.
We describe a minimally invasive procedure for removal of a distal femur locking plate using arthroscopic assistance. Using lateral accessory portals, we performed arthroscopically-assisted removal of distal locking screws. Under fluoroscopic image, proximal screws were removed from the diaphysis. The accessory lateral portal sites used to remove the distal screws were connected. Through this a...
متن کاملThe Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma
Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...
متن کاملArthroscopic removal of proximal femoral locking screws: a novel application of hip arthroscopy.
The authors describe a novel application of hip arthroscopy. Symptomatic proximal locking screws can readily be removed via an arthroscope. Not only can the proximal screw be removed with much less morbidity than in previously described procedures, but the abductor mechanisms can also be evaluated for injury sustained during the index procedure. Furthermore, scarred or inflamed trochanteric bur...
متن کاملBiomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: a cadaveric model.
OBJECTIVE The purpose of this study was to compare the biomechanical properties of bicortical with unicortical screws in a proximal tibial fracture cadaveric model. SETTING Biomechanics laboratory at a Level 1 trauma center. PATIENTS/PARTICIPANTS Eight pairs (4 male and 4 female) of elderly (average age, 79 years; range, 63 to 104 years) cadaveric tibiae. INTERVENTION Osteotomies were per...
متن کاملAdult periarticular locking plates for the treatment of pediatric and adolescent subtrochanteric hip fractures.
Two cases are presented in which adult, precontoured, lower-extremity periarticular locking plates were utilized for fixation of subtrochanteric femur fractures in pediatric patients. Recognition of the fact that a distal tibial locking plate in a small child and a proximal tibial locking plate in an adolescent anatomically ft the proximal femur in each case may provide a surgeon treating subtr...
متن کامل