Blood culture cross contamination associated with a radiometric analyzer.
نویسندگان
چکیده
During a 9-day period in August 1980 in a New Jersey hospital, three pairs of consecutively numbered blood cultures from different patients were identified as positive for the same organism (two pairs of Klebsiella pneumoniae and one pair of group A Streptococcus), for each pair, both cultures were positive in the same atmosphere, both organisms had the same sensitivities, and the second of each pair grew at least 2 days after the first and was the only positive blood culture obtained from the patient. When the hospital laboratory discontinued use of its radiometric culture analyzer for 15 days, no more consecutive pairs of positive cultures occurred. Subsequent use of the machine for 9 days with a new power unit but the original circuit boards resulted in one more similar consecutive pair (Staphylococcus epidermidis). After replacement of the entire power unit, there were no further such pairs. Examination of the machine by the manufacturer revealed a defective circuit board which resulted in inadequate needle sterilization. Laboratories which utilize radiometric analyzers should be aware of the potential for cross contamination. Recognition of such events requires alert microbiologists and infection control practitioners and a record system in the bacteriology laboratory designed to identify such clusters.
منابع مشابه
Mycobacterial cross contamination during radiometric culturing.
Pseudobacteremias in blood cultures performed on the BACTEC radiometric blood culture system have been reported. We report three cases of cross contamination with Mycobacterium avium that occurred when mycobacteria were cultured with the BACTEC 460 TB system. Malfunction of the needle sterilization heating block was demonstrated.
متن کاملآلودگی باکتریال کشتهای خون مرکز طبی کودکان تهران - فروردین تا خرداد 1383
Background: Blood culture is the criterion standard for identifying children with bacteremia. However, elevated false-positive rates are common and are associated with substantial health care costs. The aims of this prospective study were to: 1) determine the rate of blood culture contamination 2) determine variety and frequency of contaminant bacteria 3) compare the duration of hospital stay a...
متن کاملCross contamination of blood cultures associated with a multiple use venting device.
AIM To investigate cross contamination of blood cultures associated with multiple use venting devices, which are widely used in clinical microbiology laboratories to reduce labour costs. METHODS Systematic analysis of 13,880 blood culture results in a large teaching hospital where multiple use venting devices were employed. RESULTS Nine series of potential cross contamination were identifie...
متن کاملDetection of bacteremia in patients receiving antimicrobial therapy: an evaluation of the antimicrobial removal device and 16B medium.
A total of 1097 blood specimens obtained from patients receiving antibacterial antimicrobial agents were processed by three blood culture systems: standard aerobic and anaerobic radiometric media, resin-containing radiometric medium (16B; Johnston Laboratories, Cockeysville, Md.), and aerobic and anaerobic radiometric media inoculated with blood processed in an Antimicrobial Removal Device (Mar...
متن کاملبررسی آلودگیهای هوازی چهار ماده مصرفی (گوتاپرکا، ساکشن، کارپول و رولپنبه)
Statement of Problem: Today, cross infection control is an integral part of dentistry and many dental health care workers no longer question its necessity. All dental equipments and instruments could be potentially considered as a source of infection. Purpose: The aim of this study was the evaluation of aerobic contaminations of four disposable materials used in routine dental practice. Materia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 15 4 شماره
صفحات -
تاریخ انتشار 1982