In-vitro evaluation of the PediaSat continuous central venous oxygenation monitoring system.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVE In-vitro performance of the PediaSat system for continuous monitoring of central venous oxygen saturation by spectrophotometry has been evaluated. METHODS PediaSat continuous fibre-optic oximetry catheters were inserted in a black testing chamber, connected with an extracorporeal circuit and filled with human whole blood. Oxygen inflow into the cardiopulmonary bypass system was varied, and the testing chamber was perfused with blood flow of 1000 ml min(-1). Oxygen saturation values measured by PediaSat (S PediaSat O2) were compared with cooximetry (S CO-OX O2) values from simultaneously taken blood samples by Bland-Altman and simple regression analyses. RESULTS Fifty data pairs were obtained. S PediaSat O2 and S CO-OX O2 values ranged between 28-98 and 24.9-99.5%, respectively. Correlation between S PediSat O2 and S CO-OX O2 was high with an r2 value equal to 0.96 (P < 0.0001). Overall, S PediaSat O2 only slightly overestimated S CO-OX O2 (mean bias +2.9%), and limits of agreement (+/-2 SD of bias) were acceptable (-6.8/+12.6%). Sensitivity and specificity of the first differences of S PediaSat O2 and S CO-OX O2 were 1.0 and 0.92, respectively. Subgroup analysis of S CO-OX O2 values below 70% resulted in an overestimation by S PediaSat O2, with a mean bias of +5.2% and limits of agreement of -4.7 and +15.1%. CONCLUSION The current version of the PediaSat system does not reliably reflect S CO-OX O2 values below 70%, but it seems to be a useful tool providing an accurate trend of continuous central venous oxygen saturation.
منابع مشابه
Usefulness of central venous oxygen saturation monitoring during bidirectional Glenn shunt.
A PediaSat™ oximetry catheter (PediaSat: Edwards Lifesciences Co., Ltd., Irvine, CA, U. S. A.), which facilitates continuous measurement of central venous oxygen saturation (ScvO2), may be useful for surgery for pediatric congenital heart disease. We used PediaSat during a bidirectional Glenn shunt. The patient was a 13-month-old boy. Under a diagnosis of left single ventricle (pulmonary atresi...
متن کاملFiberoptic monitoring of central venous oxygen saturation (PediaSat) in small children undergoing cardiac surgery: continuous is not continuous [version 3; referees: 2 approved]
Monitoring of superior vena cava saturation (ScvO ) has Background: become routine in the management of pediatric patients undergoing cardiac surgery. The objective of our study was to evaluate the correlation between continuous ScvO by the application of a fiber-optic oximetry catheter (PediaSat) and intermittent ScvO by using standard blood gas measurements. These results were compared to tho...
متن کاملFiberoptic monitoring of central venous oxygen saturation (PediaSat) in small children undergoing cardiac surgery: continuous is not continuous
BACKGROUND Monitoring of superior vena cava saturation (ScvO 2) has become routine in the management of pediatric patients undergoing cardiac surgery. The objective of our study was to evaluate the correlation between continuous ScvO 2 by the application of a fiber-optic oximetry catheter (PediaSat) and intermittent ScvO 2 by using standard blood gas measurements. These results were compared to...
متن کاملOptoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study.
Replacement of invasive monitoring of cerebral venous oxygenation with noninvasive techniques offers great promise in the management of life-threatening neurologic illnesses including traumatic brain injury. We developed and built an optoacoustic system to noninvasively monitor cerebral venous oxygenation; the system includes a nanosecond Nd:YAG laser and a specially designed optoacoustic probe...
متن کاملContinuous Measurement of Central Venous Oxygen Saturation in Critically Ill Patients
gy allows critical care practitioners to continuously monitor and evaluate tissue oxygenation at the bedside by using a fiberoptic pulmonary artery catheter that measures mixed venous oxygen saturation (S–vO2). Placement of a pulmonary artery catheter to measure S–vO2 may not always be feasible early in resuscitation or outside the intensive care unit (ICU). A new technology that uses a modifie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of anaesthesiology
دوره 27 3 شماره
صفحات -
تاریخ انتشار 2010