The Hemochron Response RxDx heparin and protamine dosing system.
نویسندگان
چکیده
The use of dosing assays to calculate heparin and protamine dose requirements during cardiac surgery has been shown to significantly improve overall postoperative patient outcome. When patients are managed with an individualized dosing system, intraoperative and postoperative transfusion requirements and bleeding are reduced. The Hemochron RxDx system is widely used as a complement to traditional activated clotting time testing to optimize anticoagulation management. The system consists of the heparin response test, the protamine response test, and the protamine dose assay. All are modifications of the activated clotting time using either Celite (Celite Corporation, Santa Barbara, CA) or kaolin as the activator. Dosing is calculated manually using earlier version Hemochron instruments (model 801) or automatically with the Hemochron 8000 or with the early versions of the Hemochron Response and the personal digital assistant (PDA) RxDx calculator. Missing from available user options is an automated RxDx system for the Response. A study was conducted at four clinical sites to compare recently developed Response RxDx software, which eliminates the need for the PDA RxDx calculator, to the existing Hemochron 8000 RxDx and to the Response-PDA RxDx systems. Similar to the current system, the operator inputs the patient's height, weight, and gender, and the software automatically calculates the blood volume. Using the clotting times determined on the Response, bolus heparin and protamine doses and any additional heparin and protamine requirements are calculated automatically. Data were collected from 76 patients, of which, 64 patients were on pump, 11 patients were off pump, and 1 patient was converted from off to on pump. The Response estimated blood volume calculations showed a correlation coefficient of 0.989 when compared with available systems. A good correlation was also observed for the bolus heparin (r = 0.925) and protamine doses (r = 0.900) with equivalence confirmed by a paired student's t test. These data confirm that the Response RxDx system yields results that are identical (P > 0.05) to those obtained using the Hemochron 8000 RxDx or Response-PDA RxDx calculator. The Response RxDx also offers expanded user options related to blood volume limits, expanded clotting time ranges for presetting default values, and flexibility in test sequence. Case records can be printed or downloaded to a PC via the HRDM data management program. The Hemochron Response RxDx represents a complete anticoagulation management system for the cardiac surgical patient.
منابع مشابه
Hand-Held Personal Digital Assistant Program for the HEMOCHRONregistered RxDxregistered Heparin and Protamine Dosing System
The use of in vitro dosing assays for heparin and protamine during cardiac surgery has significantly improved overall postoperative patient outcome. The HEMOCHRON RxDx system (International Technidyne Corp, Edison, NJ) is widely used for anticoagulation management. Based on a series of consecutive in vitro tests, the RxDx system is used to quantify the patient’s heparin requirement (heparin res...
متن کاملA four-year experience with patient individualized heparin and protamine dosing using the Hemochron RxDx system.
Cardiac surgical case histories, collected over 4 years at Huntsville Hospital in Alabama, were reviewed for 2,293 patients. Patients were separated into two dosing groups for both heparin and protamine, hospital empirically dosed and Hemochron RxDx dosed. Review of the heparin dosing information found that incomplete data were collected for 47 patients, leaving 2,246 patients eligible to be ev...
متن کاملIncreased accuracy in heparin and protamine administration decreases bleeding: a pilot study.
Three to 5 percent of the patients undergoing cardiac surgery are reoperated because of bleeding. When a surgical cause can be excluded, heparin/protamine mismatch may be considered. Insufficient reversal of heparin and overdosing of protamine may cause postoperative bleeding. The purpose of the study was to evaluate whether a heparin-protamine titration system, Hemochron RxDx, could reduce pos...
متن کاملUtility of In Vitro Heparin and Protamine Titration for Dosing During Cardiopulmonary Bypass Surgery
Methods used to maintain a hemostatic balance during cardiopulmonary bypass surgery include the optimization of heparin and protamine dosing. Higher heparin doses have been associated with increased bleeding, while other studies have attributed reduced blood loss and transfusion requirements to lower protamine doses. We have evaluated the use of an in vitro heparin and protamine titration syste...
متن کاملComparison of Celite and Kaolin Based Heparin and Protamine Dosing Assays During Cardiac Surgery: The In Vitro Effect of Aprotinin
Both aprotinin and in vitro heparin and protamine dosing assays (RxDx System) have been shown to reduce postoperative bleeding in the cardiac surgery patient. While celite activated clotting time tests in the presence of heparin are artificially prolonged by aprotinin, the kaolin based ACT is not. In order to optimize heparin anticoagulation management during cardiac surgery when aprotinin is u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 36 3 شماره
صفحات -
تاریخ انتشار 2004