Time course of aortic valve function and root dimensions after subcoronary ross procedure for bicuspid versus tricuspid aortic valve disease.
نویسندگان
چکیده
BACKGROUND The freestanding aortic root, which is the currently preferred operative technique for pulmonary autografts, is reported to dilate and potentially promote aortic insufficiency, which has led to a controversial debate on the appropriate surgical technique, especially for congenital bicuspid aortic valve disease. Desirable data on the time course of valve function and root dimensions for the alternative subcoronary technique comparing bicuspid and tricuspid aortic valve disease are scarce. METHODS AND RESULTS Echocardiographic examinations of 31 patients with congenital bicuspid aortic valve disease (group A; age 50.5+/-11.0 years) and 51 patients with acquired tricuspid aortic valve disease (group B; age 48.1+/-15.7 years) who were operated on between June 1994 and August 1998 were performed twice postoperatively. At first and second follow-up, respectively, maximum (mean) pressure gradients were 6.0+/-2.0 (3.6+/-1.0) and 5.1+/-2.1 (2.9+/-1.1) mm Hg in group A and 6.5+/-3.5 (3.9+/-1.9) and 5.0+/-1.7 (2.9+/-1.0) mm Hg in group B (P>0.05 between groups). In group A, grade 0 aortic insufficiency at first and second follow-up occurred in 8 and 7 patients, respectively, grade 0-I in 12 and 9 patients, grade I in 9 and 11 patients, grade I-II in 1 and 0 patients, and grade II in 1 and 4 patients; in group B, grade 0 aortic insufficiency occurred in 16 and 18 patients, grade 0-I in 16 and 8 patients, grade I in 17 and 21 patients, grade I-II in 0 and 1 patient, and grade II in 0 and 1 patient (P>0.05). Aortic insufficiency decreased in 10 patients (17%). However, there was an overall tendency for aortic insufficiency to increase over time (n=23, 38%), although it remained subclinical. Aortic root dimensions did not differ between groups and were constant during follow-up. CONCLUSIONS This study provides some evidence that the function of the subcoronary pulmonary autograft in bicuspid aortic valve disease is excellent, with stable root dimensions, and is not different from that of tricuspid aortic valves at least up to 5.5 years postoperatively, which suggests the subcoronary technique should be reconsidered.
منابع مشابه
Autograft regurgitation and aortic root dimensions after the Ross procedure: the German Ross Registry experience.
BACKGROUND Autograft regurgitation and root dilatation after the Ross procedure is of major concern. We reviewed data from the German Ross Registry to document the development of autograft regurgitation and root dilatation with time and also to compare 2 different techniques of autograft implantation. METHODS AND RESULTS Between 1990 and 2006 1014 patients (786 men, 228 women; mean age 41.2+/...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملThe fate of the bicuspid valve aortopathy after aortic valve replacement.
OBJECTIVES The fate of the aortic dimensions in patients with a bicuspid aortic valve (BAV) after aortic valve replacement (AVR) is unclear. We investigated the evolution of aortic root and ascending aorta dimensions in patients with a BAV after AVR. To neutralize the effect of pathological transvalvular haemodynamics on aortic dimensions, we evaluated our hypotheses in patients with normal tra...
متن کاملRoss procedure at the crossroads.
The quest for a perfect heart valve substitute has been going on for half a century. In 1960, Lower et al1 described the feasibility of replacing the aortic valve of dogs with the native pulmonary valve. In 1967, Ross performed this procedure in humans.2 Ross transferred the pulmonary valve into the aortic root with the same technique used to implant aortic valve homograft3 (ie, the pulmonary s...
متن کاملA critical reappraisal of the Ross operation: renaissance of the subcoronary implantation technique?
BACKGROUND The autograft procedure, an option in aortic valve replacement, has undergone technical evolution. A considerable debate about the most favorable surgical technique in the Ross operation is still ongoing. Originally described as a subcoronary implant, the full root replacement technique is now the most commonly used technique to perform the Ross principle. METHODS AND RESULTS Betwe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 104 12 Suppl 1 شماره
صفحات -
تاریخ انتشار 2001