Estimation of biodynamic forces distributed on the fingers and the palm exposed to vibration.
نویسندگان
چکیده
The hand-tool coupling force in the operation of a vibrating tool is generally composed of applied force (AF) and biodynamic force (BF). There is wide interest in quantifying the coupling force. The objectives of this study are to develop an effective method for estimating the BF and to investigate its fundamental characteristics. Using the biodynamic response of the hand-arm system, such as apparent mass or mechanical impedance, and the acceleration that can be measured on vibrating tools, this study proposed an indirect method for the BF estimation. The BFs distributed on the fingers and the palm of the hand along the forearm direction (z(h)-axis) in the operations of eighteen types of tool were estimated and used to identify the distributed BF characteristics. The results indicate that the BFs depend on both the tool vibration spectrum and the biodynamic properties of the hand-arm system. The dominant BF frequency component is usually at the same frequency as the dominant vibration frequency of each tool. The BF distributed on the palm (2-98 N) is much higher than that distributed on the fingers (1-30 N) at frequencies less than 100 Hz, but these biodynamic forces (2-22 N) are comparable at higher frequencies. The palm BF on several tools with relatively low dominant frequencies (< or = 40 Hz), especially in the resonant frequency range (16-40 Hz), is comparable with the applied palm force (50-100 N). Since the resonant frequency of the palm BF is also in the range of the dominant vibration frequencies of many percussive tools, the palm BF may be related to the disorders in the wrist-arm system. The BF on the fingers is likely to be closely related to the dynamic stresses and deformations in the fingers and it may thus be used to quantify the finger vibration exposure.
منابع مشابه
Estimation of the Biodynamic Responses Distributed at Fingers and Palm Based on the Total Response of the Hand-Arm System
The major objective of this study is to develop a modelling method for estimating the biodynamic responses distributed at the fingers and the palm of the hand based on the total driving-point mechanical impedance of the entire hand-arm system. A five degrees-of-freedom (DOF) model with a set of constraints proposed in this study was used in the estimation. Three sets of mechanical impedance dat...
متن کاملExploring Biodynamic Response (Apparent Masses) of a Seated Human Body Exposed To External Excitation in Vertical Direction
In the present work, the biodynamic response behavior of seated human body subject to vibration in vertical direction have been extensively examined. The biodynamic response parameter of seated human body have been analyzed in terms of apparent masss (AM).The AM describe “to –the -body”force motion relationship at the interface of huma and seat. The present work proposed the six degrees of free...
متن کاملNumerical Solution for Gate Induced Vibration Due to Under Flow Cavitation
Among the many force s to which hydraulic structures are exposed to, the forces induced by cavitation incident are of typical hydrodynamic unknown forces. The aim of this study is to define these forces as coupled fluid-structure interaction under two dynamic effects. The first dynamic effect which incorporates facilities for dealing with cavitation fluid is based on the appearance and bursting...
متن کاملFrequency weightings based on biodynamics of fingers-hand-arm system.
The frequency weighting for assessing hand-transmitted vibration exposure is critical to obtaining a true dose-response relationship. Any valid weighting must have a solid theoretical foundation. The objectives of this study are to examine the biodynamic foundation for assessing the vibration exposure and to develop a set of biodynamic methods to formulate the frequency weightings for different...
متن کاملBiodynamic response at the palm of the human hand subjected to a random vibration.
This study investigated the biodynamic response (BR) distributed at the palm of the hand subjected to a random vibration. Twelve male subjects were used in the experiment. Each subject applied three coupling actions (grip-only, push-only, and combined grip and push) on a simulated tool handle at three different levels (50, 75, and 100 N) of palm force. This study found that the hand-arm system ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Industrial health
دوره 43 3 شماره
صفحات -
تاریخ انتشار 2005