Mechanical axis of the lower extremity determined by a new digital photographic method.
نویسندگان
چکیده
Assessment of the mechanical axis is routine during the examination of patients with lower extremity pain. Long-leg radiographic examination is the gold standard for exact measurement, but it is associated with a significant radiation dose. An alternative method to examine the mechanical axis has been warranted. This article validates a newly developed computerized photograph method to calculate the mechanical axis using a digital photograph. The location of the center of the femoral head was calculated using ink marks on both superior iliac spines. Twenty-five patients (10 women and 15 men) had both legs examined using the photographic method and long-leg radiography examination. The digital photograph method was found to be highly reliable. The interobserver absolute mean difference was 0.99°±0.85°, and the intraobserver absolute mean difference (day-to-day variation) was 1.04°±0.81°. The mechanical axis determined by the 2 methods was highly correlated (R=0.943). The long-leg radiography method was within an average of ±1.88° of the photographic method, with a 95% probability. The photographic method appears to be an effective alternative to conventional long-leg radiography. The photographic method seems convenient in the routine examination of patients with leg pain and children with suspected axial deformity and for follow-up after treatment for malalignment. Calculation coefficients for children and a possible racial difference remain to be studied.
منابع مشابه
بررسی نتایج درمانی واروس اسئوتومی دیستال فمور در 27 بیمار مبتلا به ژنوولگوم
Background: Genu valgum deformity is exaggerated valgus alignment of lower extremity mechanical axis in knee with a joint line that slopes superolaterally and is corrected by distal femoral osteotomy. In this study the results of treatment and satisfaction in patients with genu valgum were evaluated according to knee society score (KSS) and changes in pre-operation and post-operation lower extr...
متن کاملراستای اندام تحتانی در بزرگسالان
Background & Aim: Normal axial alignment restoration in lower extremities is very important for surgeons that perform reconstructive surgeries. Since normal values of axial alignment in Iranian population aren't available, normal values in western countries are used in practice. In this study axial alignment norms in Iranian adults were determined and the results were compared with those of...
متن کاملA Simple Cable Method for Intraoperative Limb Alignment Assessment
Achieving good mechanical axis of the lower extremity is of paramount importance in orthopaedic surgery, not only during joint replacement but also in fracture fixation and deformity correction. However, it is difficult to determine the mechanical axis during surgery. Many techniques have been proposed in clinical practice such as visual inspection, cable method, alignment rods, the axis board ...
متن کاملEffect of Target Impedance Selection on the Lower Extremity Assistive Exoskeleton Performance
Exoskeletons are utilized extensively in robotic rehabilitation and power augmentation purposes. One of the most recognised control algorithms utilized in this field is the impedance controller. Impedance control approach provides the capability of realizing different rehabilitation exercises by tuning the target impedance gains. Trial and error experimental approach is one of the most common m...
متن کاملA Studyof the Design of Horizontal Axis Wind Turbine
In this using paper a method is presented for the aerodynamic and structural analysis of a horizontal axis wind turbine using simplified methods. In the first part of the program the optimum rotor configuration for twist and chord is determined using the momentum and blade element theories for a rotor without coning or tilting and assuming zero drag average wind velocity. Then coning angle and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 36 8 شماره
صفحات -
تاریخ انتشار 2013