Calcification and Oxidative Modifications Are Associated With Progressive Bioprosthetic Heart Valve Dysfunction
نویسندگان
چکیده
BACKGROUND Bioprosthetic heart valves (BHVs), fabricated from glutaraldehyde-pretreated bovine pericardium or porcine aortic valves, are widely used for the surgical or interventional treatment of heart valve disease. Reoperation becomes increasingly necessary over time because of BHV dysfunction. METHODS AND RESULTS Forty-seven explanted BHV aortic valve replacements were retrieved at reoperation for clinically severe BHV dysfunction over the period 2010-2016. Clinical explant analyses of BHV leaflets for calcium (atomic absorption spectroscopy) and oxidized amino acids, per mass spectroscopy, were primary end points. Comorbidities for earlier BHV explant included diabetes mellitus and coronary artery bypass grafting. Mean calcium levels in BHV leaflets were significantly increased compared with unimplanted BHV (P<0.001); however, time to reoperation did not differ comparing calcified and noncalcified BHV. BHV dityrosine, an oxidized amino acid cross-link, was significantly increased in the explants (227.55±33.27 μmol/mol [dityrosine/tyrosine]) but was undetectable in unimplanted leaflets (P<0.001). BHV regional analyses revealed that dityrosine, ranging from 57.5 to 227.8 μmol/mol (dityrosine/tyrosine), was detectable only in the midleaflet samples, indicating the site-specific nature of dityrosine formation. 3-Chlorotyrosine, an oxidized amino acid formed by myeloperoxidase-catalyzed chlorinating oxidants, correlated with BHV calcium content in leaflet explant analyses from coronary artery bypass graft patients (r=0.62, P=0.01) but was not significantly correlated with calcification in non-coronary artery bypass graft explanted BHV. CONCLUSIONS Both increased BHV leaflet calcium levels and elevated oxidized amino acids were associated with bioprosthesis dysfunction necessitating reoperation; however, BHV calcium levels were not a determinant of implant duration, indicating a potentially important role for oxidized amino acid formation in BHV dysfunction.
منابع مشابه
Relationship Between Calcium-phosphorous Product, Native and Bioprosthetic Mitral Valve Calcifications
Calcification is a common cause of failure of natural and bioprosthetic valves (BPV). Prior research on patients with chronic kidney disease identified increased calcium-phosphorus (Ca-P) product as a risk factor for both arterial and valvular calcifications, an aspect not thoroughly investigated in general population. The aims of our study were to analyse the functional impact of native and bi...
متن کاملTrans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)
Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...
متن کاملMechanisms of bioprosthetic heart valve failure: fatigue causes collagen denaturation and glycosaminoglycan loss.
Bioprosthetic heart valve (BPHV) degeneration, characterized by extracellular matrix deterioration, remodeling, and calcification, is an important clinical problem accounting for thousands of surgeries annually. Here we report for the first time, in a series of in vitro accelerated fatigue studies (5-500 million cycles) with glutaraldehyde fixed porcine aortic valve bioprostheses, that the mech...
متن کاملPrevention of calcification in bioprosthetic heart valves: challenges and perspectives.
Surgical replacement with artificial devices has revolutionised the care of patients with severe valvular diseases. Mechanical valves are very durable, but require long-term anticoagulation. Bioprosthetic heart valves (BHVs), devices manufactured from glutaraldehyde-fixed animal tissues, do not need long-term anticoagulation, but their long-term durability is limited to 15 - 20 years, mainly be...
متن کاملCMR to Evaluate Bioprosthetic Aortic Stenosis?
SEE PAGE 785 W ith an aging population and the emergence of transcatheter valve replacement (1), the evaluation of bioprosthetic valve anatomy and function is of increasing importance. Traditional “tried and true” methods of assessing bioprosthetic valve dysfunction have relied on 2-dimensional echocardiographic techniques that evaluate leaflet morphology and mobility, as well as Doppler-based ...
متن کامل