A Proposed Maneuver to Guide Transseptal Puncture Using Real-Time Three-Dimensional Transesophageal Echocardiography: Pilot Study

نویسندگان

  • Hani M. Mahmoud
  • Mohammed A. Al-Ghamdi
  • Abdullah E. Ghabashi
  • Ashraf M. Anwar
چکیده

Aim of Study. To assess the feasibility of a new proposed maneuver "RATLe-90" using real-time three-dimensional transesophageal echocardiography (RT-3DTEE) for anatomically oriented visualization of the interatrial septum (IAS) in guiding the transseptal puncture TSP. Methods. The study included 20 patients (mean age, 60.2 ± 6.7 years; 60% males) who underwent TSP for different indications. RT-3DTEE was used to guide TSP. The proposed maneuver RATLe-90 (Rotate-Anticlockwise-Tilt-Left-90) was applied in all cases to have the anatomically oriented en face view of the IAS from the right atrial (RA) aspect. Having this anatomically oriented view, we guided the TSP catheter towards the proper puncture site according to the planned procedure. Results. Using the RATLe-90 maneuver, the anatomically oriented en face view of the IAS from the RA was obtained in all patients. We were able to guide the puncture catheter to the proper puncture site on the IAS. The 3D images obtained were clearly understood by both echocardiographers and interventionists. The RATLe-90 maneuver acquisition time was 19.9 ± 1.6 seconds. The time-to-tent was 64.8 ± 16.3 seconds. Less TEE probe manipulations were needed while guiding the TSP. Conclusions. Application of RT3D-TEE during TSP using RATLe-90 maneuver is feasible with shorter fluoroscopy time and minimizing TEE probe manipulations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A complicated transseptal puncture during Mitraclip procedure: saved by 3D-TEE.

We report a case where real-time three-dimensional transoesophageal echocardiography (3D-TEE) was able to detect a complicated transseptal puncture during a Mitraclip procedure which was not seen on the two-dimensional TEE (2D-TEE) images. This case demonstrates the incremental value of 3D-TEE during transseptal puncture.

متن کامل

Eco-X Ray Fusion for Transseptal Puncture.

In recent years, percutaneous procedures have been used increasingly to correct structural heart disease. Many of these procedures require transseptal puncture to access the left heart chambers, although complications such as cardiac tamponade and aortic perforation may occur. In certain situations, puncture of the atrial septum is required (for placement of a MitraClip device or closure of the...

متن کامل

Different transseptal puncture for different procedures: Optimization of left atrial catheterization guided by transesophageal echocardiography

BACKGROUND Left atrial catheterization through transseptal puncture is frequently performed in cardiac catheterization procedures. Appropriate transseptal puncture is critical to achieve procedural success. AIMS The aim of the study is to evaluate the feasibility of selective transseptal punctures, using a modified radiofrequency (RF) transseptal needle and transesophageal echocardiography (T...

متن کامل

First experience with real-time three-dimensional transoesophageal echocardiography-guided transseptal in patients undergoing atrial fibrillation ablation.

AIMS Transseptal (TS) puncture during atrial fibrillation (AF) ablation is a relatively safe procedure in experienced hands. However, major and minor complications cannot be completely ruled out. Real-time three-dimensional transeosophageal echocardiography (RT 3D TEE) is a novel imaging technology that permits direct visualization of the fossa ovalis in a 3D perspective, thereby sensibly lower...

متن کامل

Cryoballoon ablation for paroxysmal atrial fibrillation in the presence of an Amplatzer Septal Occluder device

Cryoballoon ablation of the pulmonary veins (CAPV) has been demonstrated to be non-inferior to radiofrequency (RF) ablation for paroxysmal atrial fibrillation (AFib). As CAPV requires a larger transseptal sheath than RF ablation, it can be challenging in the presence of an AmplatzerTM Septal Occluder (ASO) device. Real-time three-dimensional transesophageal echocardiography (RT3DTEE) provides e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015