Soft-Tissue Simulation Using the Radial Elements Method
نویسندگان
چکیده
This paper introduces the Radial Elements Method – REM for the simulation of deformable objects. The REM was conceived for the real time, dynamic simulation of deformable objects. The method uses a combination of static and dynamic approaches to simulate deformations and dynamics of highly deformable objects. The real time performance of the method and its intrinsic properties of volume conservation, modeling based in material properties and simple meshing make it particularly attractive for soft tissue modeling and surgery simulation.
منابع مشابه
محاسبه درصد خطای به وجود آمده در استفاده از فانتوم آب به جای بافت نرم برای توزیع چشمه براکیتراپی 103Pd به روش مونتکارلو
Introduction: 103Pd is a low energy source, which is used in brachytherapy. According to the standards of American Association of Physicists in Medicine, dosimetric parameters determination of brachytherapy sources before the clinical application was considered significantly important. Therfore, the present study aimed to compare the dosimetric parameters of the target source using the water ph...
متن کاملA Comparison of the Dosimetric Parameters of Cs-137 Brachytherapy Source in Different Tissues with Water Using Monte Carlo Simulation
Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...
متن کاملStudy of the Compton scattering effect of soft tissue in PET imaging by Monte Carlo method
Introduction:In PET imaging, one or both of two annihilation photons may change the direction before reaching the detector due to Compton scattering interaction in body. .Methods:This article, a Monte Carlo simulation study, examined the effect of soft tissue on this error.In this work, the PET BiographTM 6 scanner, a simple geometry of soft tissue -including a sphere of soft tissue in center ...
متن کاملThe study of neutron interactions with soft tissue using Monte Carlo simulation using the source PF
The most important part of neutron therapy treatment (NCT1) is to achieve a beam of neutrons with suitable energy and intensity, as well as the least pollution and damage. In this study, in order to correct the neutron spectrum from D-D fusion and its use in neutron therapy, a set of different materials which are called the Beam Shaping Assembly (BSA) was placed in the direction of energy 2.45 ...
متن کاملSoft Tissue Modeling Using ANFIS for Training Diagnosis of Breast Cancer in Haptic Simulator
Soft tissue modeling for the creation of a haptic simulator for training medical skills has been the focus of many attempts up to now. In soft tissue modeling the most important parameter considered is its being real-time, as well as its accuracy and sensitivity. In this paper, ANFIS approach is used to present a nonlinear model for soft tissue. The required data for training the neuro-fuzzy mo...