Isolated mitral and aortic valve replacement with the St. Jude Medical valve: a midterm follow-up.

نویسندگان

  • Alfredo José Rodrigues
  • Paulo Roberto Barbosa Evora
  • Solange Bassetto
  • Lafaiete Alves
  • Adilson Scorzoni Filho
  • Walter Villela A Vicente
چکیده

BACKGROUND In our country, the biological valvular prostheses predominate, considering the difficulties related to anticoagulation, even in young patients, in spite of the need for repeated operations due to the degeneration of the bioprostheses. OBJECTIVES To report our consecutive series of recipients of isolated St Jude Medical mechanical valve prosthesis in the mitral (MVR) or aortic (AVR) position. METHODS Data from patients operated between January 1995 and December 2003 were revised in order to determine patient survival and prosthesis-related events up to December 2006. RESULTS One hundred sixty eight patients had MVR and 117 had AVR. In the MVR cohort, the mean age was 45 years, 75% were 55 years old or younger, and 65% were females. In the ARV cohort, the mean age was 45 years, 66% were 55 years old or younger and 69% were males. Operative mortality for AVR and MVR was 7% and 7.5%, respectively. Freedom from late mortality was 81.8% at 10 years for MVR and 83% for AVR (p=0.752). Freedom from valve-related death at 10 years for the MVR cohort and AVR was 85.6% and 88.7%, respectively (p=0.698). In the MVR cohort, the freedom from reoperation was 97% and 99% in the AVR cohort (p=0.335). Freedom from thromboembolic events was 82% in the MVR cohort and 98% in the AVR cohort (p=0.049). Freedom from bleeding was 71% in the MVR cohort and 86% n the AVR cohort (0.579). Freedom from endocarditis was 98% in the MVR cohort and 99% in the AVR cohort (p=0.534). CONCLUSIONS This series of predominantly young adult patients undergoing isolated MVR and AVR with the St Jude Medical mechanical prosthesis confirms the good performance of this valve prosthesis in agreement with previous reports.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?

BACKGROUND The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2) <indexed effective orifice area ≤ 0.85 cm(2)/m(2)) on midterm outcomes after isolated aortic valve replacement with a 17-mm St. Jude Medical Regent valve in a large series of patients, and to determine if these effects are influenced by patient confounding variables. M...

متن کامل

Midterm Follow-Up of Haemodynamic Performance of the St. Jude Medical Trifecta Aortic Bioprosthesis in Young Patients Under 65

Method Thirty consecutive patients undergoing aortic valve replacement using the St. Jude Medical Trifecta valve at a single UK centre over a 48-month period were included in this study. Patients undergoing concomitant cardiac procedures were included. All implanted valves were 21, 23, 25 and 27 mm in size. Assessment of haemodynamic function was carried out using transthoracic echocardiography...

متن کامل

Three Different Imaging Modalities of a Patient with the Aortic Coarctation

The patient was a 19 year-old woman with the diagnosis of resistant hypertension, although she was under treatment of three classes of anti-hypertensive drugs (beta blocker, angiotensin receptor blocker, diuretic) for more than one year. In physical examination there was only a significant difference between the systolic blood pressure of upper and lower extremities (200 vs. 120 mmHg), without ...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Twenty-five year experience with the St. Jude medical mechanical valve prosthesis.

BACKGROUND We evaluated all adult St. Jude mechanical valve recipients at our institution since the initial implant in January 1979 and now present our 25-year experience. METHODS Nine hundred forty-five valve recipients were followed prospectively at 12-month intervals from January 1979 to December 2007. RESULTS Operative mortality was 3% in the aortic valve recipients and 5% in the mitral...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de cardiologia

دوره 93 3  شماره 

صفحات  -

تاریخ انتشار 2009