Quantification of methylmalonic acid in human plasma with hydrophilic interaction liquid chromatography separation and mass spectrometric detection.
نویسندگان
چکیده
BACKGROUND Measurement of methylmalonic acid (MMA) in serum or plasma is useful for diagnosing cobalamin deficiency. We developed a method for quantifying MMA in plasma based on hydrophilic interaction liquid chromatography (HILIC) and single-stage negative electrospray ionization (ESI) mass spectrometry. METHODS We deproteinized plasma samples (200 microL) with 800 microL acidified acetonitrile containing 0.17 micromol/L deuterated MMA (D(3)-MMA) internal standard, centrifuged the samples, and injected 4 microL of the supernatant into the LC-MS instrument. Separation was achieved within 3 min on a Merck SeQuant ZIC-HILIC column with a mobile phase consisting of 4 volumes acetonitrile plus 1 volume 100 mmol/L ammonium acetate buffer, pH 4.5, at a flow rate of 400 microL/min. Subsequent column washing and reconditioning contributed to a total run time of 10 min. MMA and D(3)-MMA were quantified by single-ion monitoring (m/z 117.2 and 120.2, respectively) in negative ESI mode at a drying-gas flow rate of 10 L/min, 300 degrees C, and a capillary voltage of 3.0 kV. RESULTS The estimated limits of MMA quantification and detection were 0.09 micromol/L and 0.03 micromol/L, respectively, in plasma. The assay was linear to 200 micromol/L. Interassay and intraassay CVs were < or = 5% at all tested concentrations. Recoveries were 90%-93%. CONCLUSIONS This robust assay allows analysis of MMA in human plasma without derivatization. Sample preparation is simple and suitable for automation.
منابع مشابه
Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...
متن کاملComparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry
A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...
متن کاملMethod validation of clonidine hydrochloride in human plasma by LC-MS technique
A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile–water 60:40 (v/v), and 0.2% formic acid 20 µL of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm×30 m...
متن کاملA quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...
متن کاملQuantification of identical and unique segments in ethylene-propylene copolymers using two dimensional liquid chromatography with infra-red detection
Hyphenating High Temperature High Performance Liquid Chromatography (HT-HPLC) with High Temperature Size Exclusion Chromatography (HT-SEC) (High Temperature Two Dimensional Liquid Chromatography (HT-HPLC x HT-SEC or HT 2D-LC)) leads to an isocratic elution in the second dimension, which in turn enables to use IR detector (quantitative detection) for monitoring the eluting polymers. Experimental...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 54 12 شماره
صفحات -
تاریخ انتشار 2008