Feedback cooling of a cantilever's fundamental mode below 5 mK.

نویسندگان

  • M Poggio
  • C L Degen
  • H J Mamin
  • D Rugar
چکیده

We cool the fundamental mechanical mode of an ultrasoft silicon cantilever from a base temperature of 2.2 K down to 2.9+/-0.3 mK using active optomechanical feedback. The lowest observed mode temperature is consistent with limits determined by the properties of the cantilever and by the measurement noise. For high feedback gain, the driven cantilever motion is found to suppress or "squash" the optical interferometer intensity noise below the shot noise level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical read out and feedback cooling of a nanostring optomechanical cavity

Optical measurement of the motion of a 940 kHz mechanical resonance of a silicon nitride nanostring resonator is demonstrated with a read out noise imprecision reaching 37 dB below that of the resonator’s zero-point fluctuations. Via intensity modulation of the optical probe laser, radiation pressure feedback is used to cool and damp the mechanical mode from an initial room temperature occupanc...

متن کامل

Feedback cooling of a one-electron oscillator.

A one-electron oscillator is cooled from 5.2 K to 850 mK using electronic feedback. Novel quantum jump thermometry reveals a Boltzmann distribution of oscillator energies and directly measures the corresponding temperature. The ratio of electron temperature and damping rate (also directly measured) is observed to be a fluctuation-dissipation invariant, independent of feedback gain, as predicted...

متن کامل

Stable, mode-matched, medium-finesse optical cavity incorporating a microcantilever mirror: optical characterization and laser cooling.

A stable optical resonator has been built using a 30-microm-wide, metal-coated microcantilever as one mirror. The second mirror was a 12.7-mm-diameter concave dielectric mirror. By positioning the two mirrors 75 mm apart in a near-hemispherical configuration, a Fabry-Perot cavity with a finesse equal to 55 was achieved. The finesse was limited by the optical loss in the cantilever's metal coati...

متن کامل

Optical dilution and feedback cooling of a gram-scale oscillator to 6.9 mK.

We report on the use of a radiation pressure induced restoring force, the optical spring effect, to optically dilute the mechanical damping of a 1 g suspended mirror, which is then cooled by active feedback (cold damping). Optical dilution relaxes the limit on cooling imposed by mechanical losses, allowing the oscillator mode to reach a minimum temperature of 6.9 mK, a factor of approximately 4...

متن کامل

On-chip magnetic cooling of a nanoelectronic device

We demonstrate significant cooling of electrons in a nanostructure below 10 mK by demagnetisation of thin-film copper on a silicon chip. Our approach overcomes the typical bottleneck of weak electron-phonon scattering by coupling the electrons directly to a bath of refrigerated nuclei, rather than cooling via phonons in the host lattice. Consequently, weak electron-phonon scattering becomes an ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 99 1  شماره 

صفحات  -

تاریخ انتشار 2007