Pulsed electron avalanche knife (PEAK-fc) for dissection of retinal tissue.
نویسندگان
چکیده
OBJECTIVE To evaluate the effectiveness and precision of tractionless retinal tissue dissection by the advanced version of the pulsed electron avalanche knife for fine cutting (PEAK-fc; Carl Zeiss Meditec, Jena, Germany). METHODS Porcine retina (in vivo) and human retina (in vitro) were incised with the PEAK-fc using various pulse parameters. The globes were then processed for light microscopy. Evaluation of all specimens focused on depth of the retinal cuts and on the degree of collateral damage. RESULTS Retinal cuts performed both in vivo on porcine eyes and on human donor eyes showed very sharp edges with only little collateral damage. With probes of 600 mum in length, the optimal pulse parameters for precise and reproducible cutting of the retina were an amplitude of 350 to 380 V, a repetition rate of 300 Hz, and 30 "minipulses" per pulse of 100-microsecond duration. With increasing voltage, cuts also affected the retinal pigment epithelium and the choroid, followed by intravitreal bleeding during in vivo application. CONCLUSION We demonstrated that PEAK-fc is capable of precisely cutting retinal tissue in vivo and in vitro using optimal pulse parameters. Further in vivo studies will be necessary to determine the efficacy of this new tractionless cutting device in vitreoretinal surgery.
منابع مشابه
SURGICAL TECHNIQUES Pulsed electron avalanche knife: new technology for cataract surgery
Background: The pulsed electron avalanche knife (PEAK-fc) is a new pulsed electrosurgical device that allows for precise, ‘‘cold’’ and traction-free tissue dissection. Aim: To evaluate the surgical applicability, safety and potential complications of PEAK-fc in complicated cataract surgery. Methods: The study included five children with congenital cataracts, two patients with advanced senile ca...
متن کاملPulsed electron avalanche knife: new technology for cataract surgery.
BACKGROUND The pulsed electron avalanche knife (PEAK-fc) is a new pulsed electrosurgical device that allows for precise, "cold" and traction-free tissue dissection. AIM To evaluate the surgical applicability, safety and potential complications of PEAK-fc in complicated cataract surgery. METHODS The study included five children with congenital cataracts, two patients with advanced senile cat...
متن کاملPulsed electron avalanche knife for capsulotomy in congenital and mature cataract.
The pulsed electron avalanche knife (PEAK-fc, Carl Zeiss Meditec) is an electrosurgical cutting device that allows precise "cold" and traction-free tissue dissection. We describe its applicability and safety for anterior capsulotomy in a child with congenital cataract and an adult patient with mature cataract. The PEAK-fc was set at a voltage of 600 V and a pulse repetition rate of 80 Hz. Anter...
متن کاملPulsed electron avalanche knife in vitreoretinal surgery.
PURPOSE To evaluate the advantages, disadvantages, safety, and surgical applicability of the pulsed electron avalanche knife (PEAK-fc), a new electrosurgical knife for "cold" and tractionless cutting, in vitreoretinal surgery. PEAK-fc is equipped with an integrated fiberoptic that makes bimanual procedures in intraocular surgery possible. METHODS A prospective consecutive trial of 18 eyes in ...
متن کاملEffects of the pulsed electron avalanche knife on retinal tissue.
OBJECTIVES To evaluate the precision of retinal tissue dissection by the pulsed electron avalanche knife (PEAK) and to assess possible toxic effects from this device. METHODS To demonstrate precision of cutting, bovine retina (in vitro) and rabbit retina (in vivo) were incised with the PEAK. Samples were examined by scanning electron microscopy and histologic examination (light microscopy). T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of ophthalmology
دوره 123 10 شماره
صفحات -
تاریخ انتشار 2005