Time Dependent Dielectric Breakdown in Copper Low-k Interconnects: Mechanisms and Reliability Models

نویسنده

  • Terence K.S. Wong
چکیده

The time dependent dielectric breakdown phenomenon in copper low-k damascene interconnects for ultra large-scale integration is reviewed. The loss of insulation between neighboring interconnects represents an emerging back end-of-the-line reliability issue that is not fully understood. After describing the main dielectric leakage mechanisms in low-k materials (Poole-Frenkel and Schottky emission), the major dielectric reliability models that had appeared in the literature are discussed, namely: the Lloyd model, 1/E model, thermochemical E model, E models, E model and the Haase model. These models can be broadly categorized into those that consider only intrinsic breakdown (Lloyd, 1/E, E and Haase) and those that take into account copper migration in low-k materials (E, E). For each model, the physical assumptions and the proposed breakdown mechanism will be discussed, together with the quantitative relationship predicting the time to breakdown and supporting experimental data. Experimental attempts on validation of dielectric reliability models using data obtained from low field stressing are briefly discussed. The phenomenon of soft breakdown, which often precedes hard breakdown in porous ultra low-k materials, is highlighted for future research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Methodology to determine the impact of linewidth variation on chip scale copper/low-k backend dielectric breakdown

0026-2714/$ see front matter 2010 Elsevier Ltd. A doi:10.1016/j.microrel.2010.07.091 * Corresponding author. Tel.: +1 404 894 4793; fax E-mail address: [email protected] (L. Mil Low-k time-dependent dielectric breakdown (TDDB) has been found to be a function of metal linewidth, when the distance between the lines is constant. Modeling requires determining the relationship between TDDB ...

متن کامل

Evidence of ultra-low-k dielectric material degradation and nanostructure alteration of the Cu/ultra-low-k interconnects in time-dependent dielectric breakdown failure

alteration of the Cu/ultra-low-k interconnects in time-dependent dielectric breakdown failure Jeffrey C. K. Lam, Maggie Y. M. Huang, Tsu Hau Ng, Mohammed Khalid Bin Dawood, Fan Zhang, Anyan Du, Handong Sun, Zexiang Shen, and Zhihong Mai GLOBALFOUNDRIES Singapore Pte Ltd, Woodlands Industrial Park D, Street 2, Singapore 738406 Division of Physics and Applied Physics, School of Physical and Mathe...

متن کامل

Chip-Package Interaction and Reliability Impact on Cu/Low-k Interconnects

The exponential growth in device density has yielded high-performance microprocessors containing two billion transistors [1]. The path toward such integration continues to require the implementation of new materials, processes, and design for interconnect and packaging structures. Since 1997, copper (Cu), which has a lower resistivity than aluminum (Al), has been selected as an interconnect mat...

متن کامل

Post-Routing Back-End-Of-Line Layout Optimization for Improved Time-Dependent Dielectric Breakdown Reliability

Time-dependent dielectric breakdown (TDDB) is becoming a critical reliability issue, since the electric field across dielectric increases as technology scales. Moreover, dielectric reliability is aggravated when interconnect spacings vary due to (vias and wires) mask misalignment. Although dielectric reliability can be mitigated by a larger interconnect pitch, such a guardband leads to signific...

متن کامل

Time dependent dielectric breakdown in a low-k interlevel dielectric

Intralevel Time Dependent Dielectric Breakdown (TDDB) was studied in interdigitated comb structures comprised of standard Cu metallization and a low-k interlevel dielectric. The failure distribution was found to be best represented as being lognormal with sigma increasing as the field decreased. Kinetic studies revealed an exponential dependence on the electric field that fits 1/E closer than –...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2012