Comparison of Direct Normal Irradiance Derived from Silicon and Thermopile Global Hemispherical Radiation Detectors: Preprint
نویسندگان
چکیده
Concentrating solar applications utilize direct normal irradiance (DNI) radiation, a measurement rarely available. The solar concentrator industry has begun to deploy numerous measurement stations to prospect for suitable system deployment sites. Rotating shadowband radiometers (RSR) using silicon photodiodes as detectors are typically deployed. This paper compares direct beam estimates from RSR to a total hemispherical measuring radiometer (SPN1) multiple fast thermopiles. These detectors simultaneously measure total and diffuse radiation from which DNI can be computed. Both the SPN1 and RSR-derived DNI are compared to DNI measured with thermopile pyrheliometers. Our comparison shows that the SPN1 radiometer DNI estimated uncertainty is somewhat greater than, and on the same order as, the RSR DNI estimates for DNI magnitudes useful to concentrator technologies.
منابع مشابه
Evaluation of Photodiode and Thermopile Pyranometers for Photovoltaic Applications: Preprint
Accurately determining photovoltaic (PV) module performance in the field requires measuring solar irradiance reaching the PV panel at a high level of accuracy and known uncertainty. Silicon detectors used in various solar energy measuring instruments that include reference cells are a potentially attractive choice for multiple reasons, including faster responsivity than thermopile detectors, ch...
متن کاملTechnical guide to Set Up a Spectral Solar Direct Normal Irradiance Permanent Station: Study Area- Hannover, Germany
The spectral Direct Normal Irradiance (SDNI) is a basic radiometric quantity from which many other quantities can be derived. It provides not only information about the spectral and distribution of the direct solar radiation reaching a particular location. Accurate knowledge about the spectral direct irradiance shall enable us to gain new scientific results in the: determination of cloud effect...
متن کاملA New Database of Global and Direct Solar Radiation Using the Eastern Meteosat Satellite, Models and Validation
We present a new database of solar radiation at ground level for Eastern Europe and Africa, the Middle East and Asia, estimated using satellite images from the Meteosat East geostationary satellites. The method presented calculates global horizontal (G) and direct normal irradiance (DNI) at hourly intervals, using the full Meteosat archive from 1998 to present. Validation of the estimated globa...
متن کاملUNCOOLED THERMOPILE INFRARED DETECTOR LINEAR ARRAYS WITH DEFECTIVITY GREATER THAN 10 cmHzln/W
We have fabricated 63-element linear arrays of rnicromachined thermopile infrared detectors on silicon substrates. Each detector consists of a suspended silicon nitride membrane with 11 thermocouples of sputtered Bi-Te and Bi-Sb-Te films. At room temperature these detectors exhibit response times of 99 ms, zero frequency D* values of 1.4x109 cmHz’n/W and responsivity values of 1100 V/W when vie...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کامل