Venous and capillary whole blood glucose from the fingertip D. Type of Test: Quantitative amperometric assay, glucose dehydrogenase (mutant GDH-PQQ) E. Applicant: Roche Diagnostics Corporation F. Proprietary and Established Names: ACCU-CHEK Performa Blood Glucose Monitoring System
ثبت نشده
چکیده
منابع مشابه
Analytical validation of the new plasma calibrated Accu-Chek Test Strips (Roche Diagnostics).
BACKGROUND The Accu-Chek Inform glucose monitor is a point-of-care system for testing blood glucose. New test strips, calibrated to deliver glucose plasma-like values, were launched on the market in May 2005. The aim of our study was to perform analytical validation of these new strips. METHODS We compared the new plasma strips with whole blood strips; results for the plasma strips with plasm...
متن کاملAssessment of three frequently used blood glucose monitoring devices in clinical routine.
BACKGROUND Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aime...
متن کاملمقایسه قدرت دستگاه گلوکومتر Accu-chek با Elite در تشخیص دیابت با استفاده از خونریزی متعاقب Probing
Abstract Background: Recent studies have assessed the validity of glucometer devices in estimating the glucose level of gingival blood during routine periodontal examination (Bleeding On Probing). The purpose of this study was to evaluate whether blood oozing from gingival tissues during routine periodontal examination can be used for determining g...
متن کاملSelf-monitoring of blood glucose levels requires intensive training for use of meters to obtain reliable and clinically relevant measurements.
BACKGROUND Anecdotal reports from pediatric sites have indicated that some blood glucose meters may display wrong and misleading numbers rather than error indications, when operated in deviation from the instructions for use (IFU), eg by manipulating the strip during the count-down phase. METHODS This study was performed with 60 patients with diabetes (32 female, 28 male, 21 type 1, 39 type 2...
متن کاملContinuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode.
The performance of an amperometric biosensor, consisting of a subcutaneously implanted miniature (0.29 mm diameter, 5 x 10(-4) cm2 mass transporting area), 90 s 10-90% rise/decay time glucose electrode, and an on-the-skin electrocardiogram Ag/AgCl electrode was tested in an unconstrained, naturally diabetic, brittle, type I, insulin-dependent chimpanzee. The chimpanzee was trained to wear on he...