Assessing reperfusion with whole-brain arterial spin labeling: a noninvasive alternative to gadolinium.

نویسندگان

  • Raymond V Mirasol
  • Reinoud P H Bokkers
  • Daymara A Hernandez
  • José G Merino
  • Marie Luby
  • Steven Warach
  • Lawrence L Latour
چکیده

BACKGROUND AND PURPOSE Arterial spin labeling (ASL) is a perfusion imaging technique that does not require gadolinium. The study aimed to assess the reliability of ASL for evaluating reperfusion in acute ischemic stroke in comparison with dynamic susceptibility contrast (DSC) imaging. METHODS The study included 24 patients with acute ischemic stroke on admission and 24-hour follow-up ASL and DSC scans. Two readers rated images for interpretability and evidence of reperfusion. Cohen unweighted κ was used to assess (1) inter-rater reliability between readers for determining interpretability and the presence of reperfusion, (2) agreement between ASL and DSC for determining reperfusion for individual raters, and (3) agreement between ASL and DSC for determining reperfusion after consensus. RESULTS Inter-rater reliability for both ASL and DSC was moderate to good (κ of 0.67 versus 0.55, respectively). Reader 1 rated 16 patients as having interpretable ASL and DSC when compared with 15 patients for reader 2. The κ between ASL and DSC for determining reperfusion was 0.50 for reader 1 and 0.595 for reader 2. After consensus, 18 ASL and 17 DSC image sets were rated interpretable for reperfusion and 13 had both interpretable ASL and DSC scans, yielding a κ for assessment of reperfusion of 0.8. CONCLUSIONS Inter-rater reliability of ASL and DSC was moderate to good. Agreement between ASL and DSC for determining reperfusion was moderate for each individual rater and increased substantially after consensus. ASL is a noninvasive and practical alternative to DSC for reperfusion assessments in patients with confirmed acute ischemic stroke.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Whole-brain arterial spin labeling perfusion MRI in patients with acute stroke.

BACKGROUND AND PURPOSE Perfusion MRI can be used to identify patients with acute ischemic stroke who may benefit from reperfusion therapies. The risk of nephrogenic systemic fibrosis, however, limits the use of contrast agents. Our objective was to evaluate the ability of arterial spin labeling (ASL), an alternative noninvasive perfusion technique, to detect perfusion deficits compared with dyn...

متن کامل

Clinical utility of arterial spin-labeling as a confirmatory test for suspected brain death.

Diagnosis of brain death is made on the basis of 3 essential findings: coma, absence of brain stem reflexes, and apnea. Although confirmatory tests are not mandatory in most situations, additional testing may be necessary to declare brain death in patients in whom results of specific components of clinical testing cannot be reliably evaluated. Recently, arterial spin-labeling has been incorpora...

متن کامل

Arterial spin labeling MRI to measure peak-exercise calf muscle perfusion reproducibly discriminates peripheral arterial disease from normal

Background Prior work demonstrated the utility of first-pass gadolinium-enhanced calf muscle perfusion MRI in patients with peripheral arterial disease (PAD). However patients with PAD often have advanced renal disease which prohibits the use of gadolinium-based contrast agents due to the concern for nephrogenic systemic fibrosis. ASL for quantification of calf muscle blood flow could provide a...

متن کامل

A protocol for assessing subtraction errors of arterial spin-tagging perfusion techniques in human brain.

A protocol for assessing signal contributions from static tissue (subtraction errors) in perfusion images acquired with arterial spin-labeling (ASL) techniques in human brain is proposed. The method exploits the reduction of blood T(1) caused by the clinically available paramagnetic contrast agent, gadopentetate dimeglumine (Gd-DTPA). The protocol is demonstrated clinically with multislice FAIR...

متن کامل

Noninvasive Evaluation of CBF and Perfusion Delay of Moyamoya Disease Using Arterial Spin-Labeling MRI with Multiple Postlabeling Delays: Comparison with 15O-Gas PET and DSC-MRI.

BACKGROUND AND PURPOSE Arterial spin-labeling MR imaging with multiple postlabeling delays has a potential to evaluate various hemodynamic parameters. To clarify whether arterial spin-labeling MR imaging can identify CBF and perfusion delay in patients with Moyamoya disease, we compared arterial spin-labeling, DSC, and 15O-gas PET in terms of their ability to identify these parameters. MATERI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 45 2  شماره 

صفحات  -

تاریخ انتشار 2014