Blood gas measurement during exercise: a comparative study between arterialized earlobe sampling and direct arterial puncture in adults.

نویسندگان

  • I Fajac
  • J Texereau
  • V Rivoal
  • J F Dessanges
  • A T Dinh-Xuan
  • J Dall'Ava-Santucci
چکیده

Sampling arterialized earlobe blood is thought to be easier and less painful than direct arterial puncture, and to allow measurement of blood gas values during exercise without the need to insert an arterial cannula. However, arterialized earlobe oxygen tension (PO2) often underestimates arterial PO2 at rest, and is not fully validated during exercise. We have therefore conducted a prospective study to compare values of PO2 and carbon dioxide tension (PCO2) and the discomfort experienced by adult subjects undergoing the two methods of blood sampling during exercise. Seventy consecutive adult patients were studied. Blood samples were drawn simultaneously from the radial artery and arterialized earlobe of each patient during the last minute of an 8 min exercise. Values of PO2 and PCO2 were measured by means of blood gas electrodes. The correlation coefficients between the two samples were 0.92 for PO2 and 0.91 for PCO2. However, the bias and the limits of agreement between the two methods were wide for PO2 (mean+/-2SD of the differences between the two methods: 0.63+/-1.50 kPa (4.7+/-11.2 mmHg)). The bias and the limits of agreement were smaller for PCO2. Patients felt that the earlobe method was not associated with less discomfort than radial artery puncture. We conclude that arterialized earlobe blood oxygen tension is not a good substitute for arterial oxygen tension during exercise, and should not be used to assess arterial oxygen tension in adults during exercise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of arterial blood gas values from arterialized earlobe blood gas values in patients treated with mechanical ventilation

BACKGROUND/OBJECTIVE Arterial blood gas (ABG) analysis is useful in evaluation of the clinical condition of critically ill patients; however, arterial puncture or insertion of an arterial catheter may sometimes be difficult and cause many complications. Arterialized ear lobe blood samples have been described as adequate to gauge gas exchange in acute and chronically ill pediatric patients. PU...

متن کامل

Differences in PO2 and PCO2 between arterial and arterialized earlobe samples.

Arterialized ear lobe blood samples have been described as adequate to gauge gas exchange in acute and chronically ill patients. It is a safe procedure, usually performed by medical technicians. We have conducted a prospective study to verify the validity of this method. One hundred and fifteen consecutive adult patients were studied. Blood samples were drawn simultaneously from arterialized ea...

متن کامل

Earlobe arterialized capillary blood gas analysis in the intensive care unit: a pilot study

BACKGROUND Earlobe arterialized capillary blood gas analysis can be used to estimate arterial gas content and may be suitable for diagnosis and management of critically ill patients. However, its utility and applicability in the ICU setting remains unexplored. METHODS A prospective observational validation study was designed to evaluate this technique in a cohort of mechanically ventilated ad...

متن کامل

Use of a combined oxygen and carbon dioxide transcutaneous electrode in the estimation of gas exchange during exercise.

BACKGROUND Accurate and reliable measurement of gas exchange during exercise has traditionally involved arterial cannulation. Non-invasive devices to estimate arterial oxygen (O2) and carbon dioxide (CO2) tensions are now available. A method has been devised and evaluated for measuring gas exchange during exercise with a combined transcutaneous O2 and CO2 electrode. METHODS Symptom limited ex...

متن کامل

Arterialised earlobe blood gas analysis: an underused technique.

BACKGROUND Techniques for sampling arterialised capillary blood from the finger pulp and the earlobe were first described over two decades ago but, although close agreement between arterial values and earlobe samples has been demonstrated in normal subjects, this technique is not in common usage. METHODS Forty patients with chronic lung disease and a wide range of arterial blood gas values we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 1998