Liquid-chromatographic determination of inosine, xanthine, and hypoxanthine in uremic patients receiving hemodialysis treatment.
نویسندگان
چکیده
We used a liquid-chromatographic method to measure xanthine, hypoxanthine, and inosine in plasma of uremic patients before and after hemodialysis. The concentrations of all three were higher than in normal subjects. After dialysis treatment, the values were significantly lower than before dialysis, but still above normal.
منابع مشابه
Simultaneous determination of purine nucleotides, their metabolites and beta-nicotinamide adenine dinucleotide in cerebellar granule cells by ion-pair high performance liquid chromatography.
The method described here allows the quantitative simultaneous determination of adenosine 5'-triphosphate, adenosine 5'-diphosphate, adenosine 5'-monophosphate, adenosine, guanosine 5'-triphosphate, guanosine 5'-diphosphate, guanosine, inosine 5'-monophosphate, inosine, uric acid, xanthine, hypoxanthine and beta-nicotinamide adenine dinucleotide by ion-pair high performance liquid chromatograph...
متن کاملA high-performance liquid chromatographic method for the determination of hypoxanthine, xanthine, uric acid and allantoin in serum.
A method was developed for the simultaneous determination of hypoxanthine, xanthine, uric acid and allantoin based on isocratic reversed-phase chromatography. This HPLC-method additionally allows the direct determination with UV-detection of inosine-5'-phosphate, uridine, thymine, orotic acid, allopurinol and oxipurinol, besides hypoxanthine, xanthine and uric acid in the same chromatographic r...
متن کاملSimultaneous liquid-chromatographic determination of hypoxanthine, xanthine, urate, and creatinine in cerebrospinal fluid, with direct injection.
In this method for simultaneously determining hypoxanthine, xanthine, urate, and creatinine in cerebrospinal fluid, centrifuged sample is directly injected on a reversed-phase liquid-chromatographic column. On elution with potassium phosphate buffer the compounds are quantified by their absorbance at 260 nm. Random error (CV) was between 1.2 and 3.4% and analytical recoveries were 99-104% at ph...
متن کاملScreening of UV-absorbing solutes in uremic serum by reversed phase HPLC--change of blood levels in different therapies.
In order to screen UV-absorbing solutes in large numbers of uremic serum samples, an automated liquid chromatographic method was developed. The method proved to be reliable and reproducible in more than 500 analyses. HPLC separation was performed using gradient elution on a 25-cm Ultrasphere Octyl reversed phase column, with 5 microns particles. Characteristic profiles for the uremic state were...
متن کاملDialysis modality-dependent changes in serum metabolites: accumulation of inosine and hypoxanthine in patients on haemodialysis.
BACKGROUND The body metabolism of patients with end-stage renal disease may be altered in response to long-term dialysis treatment. Moreover, the pattern of serum metabolites could change depending on the type of dialysis modality used. However, dialysis modality-dependent changes in serum metabolites are poorly understood. Our aim was to profile comprehensively serum metabolites by exploiting ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 33 12 شماره
صفحات -
تاریخ انتشار 1987