Illuminance of neonatal units.
نویسندگان
چکیده
We have measured the illuminance (brightness) of seven neonatal units during both the day and the night. When the units were lit solely by fluorescent tubes the mean illuminance was 348 lux (range 192-690). During the day the mean illuminance was 470 lux (range 236-905). The high dependency regions in four of the seven units were significantly brighter than the corresponding low dependency nurseries at all times. In two of these units there is a policy of reducing the amount of artificial light in the low dependency areas at night, and in these the normal mean illuminance was 50 lux. We have measured the general levels of illumination to which a neonate might be exposed; the ocular exposure to light of a neonate depends, however, on both physical and biological factors and more research is required before an accurate estimate can be made.
منابع مشابه
ارزیابی روشنایی مصنوعی داخلی و محوطهای در محیط کاری بیمارستانهای شهر همدان
Background & Objectives: Comfort lighting is one of the most important topics, which provides optimum physical conditions in general environment and workplaces such as hospitals. This study aimed to evaluate general, local and area artificial illumination of Hamadan city hospitals . Methods : In this descriptive-analytical study, general, local and area artificial illumina...
متن کاملInternational comparison of the illuminance responsivity scales and units of luminous flux maintained at the HUT (Finland) and the NIST (USA)
An international comparison has been conducted to compare the illuminance responsivity scales (A/lx) and the units of luminous ux (lm) maintained at the National Institute of Standards and Technology (NIST, USA) and the Helsinki University of Technology (HUT, Finland). Both laboratories realize the illuminance unit by absolutely calibrated photometers and the luminous ux unit by the absolut...
متن کاملDepth-discrimination thresholds as a function of binocular differences of retinal illuminance at scotopic and photopic levels.
The precision of depth discrimination has been measured in a two-rod test apparatus involving real-depth cues. The effects of two variables have been studied: (a) the level of equal retinal illuminance presented to the two eyes; and (b) the difference in the level of the retinal illuminance presented to the two eyes. It has been found that depth discrimination in this test varies as a function ...
متن کاملPain Management Perceptions of the Neonatal Nurses in NICUs and Neonatal Units in Ardebil, Iran
Background: This study aimed to determine neonatal nurses’ perceptions of knowledge and practice in pain management in NICUs & neonatal units. Methods: A cross-sectional descriptive study design was used. A total of 120 neonatal nurses who working in NICUs & neonatal units in Ardebil province, Iran were selected using the convenience sampling technique. A questionnaire of Nurses’ Perceptions of...
متن کاملTime course of early mesopic adaptation to luminance decrements and recovery of spatial resolution
The time course of recovery of spatial resolution following adaptation to a uniform field was measured for test probes presented at lower illuminance than the adapting field. Six observers were tested in a Maxwellian-view system using 20 degrees adapting fields of 1.6-2.6 log photopic trolands. Test stimuli were 7 degrees, 250 ms Gabor patches (1 and 6 cpd) of mean retinal illuminance 2-3 log u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood
دوره 65 7 Spec No شماره
صفحات -
تاریخ انتشار 1990