CMR at 3 Tesla using a large flexible surface coil: initial experience

نویسندگان

  • KS Nayak
  • P Varadarajan
چکیده

The choice of receiver coils used in high-field CMR, such as at 3T, is critical. Because of reduced RF penetration, a broader surface area is required. Too large an area requires imaging with a large FOV, which increases scan-time. This can often be reduced with parallel reconstruction techniques, or k-t space techniques (if the additional FOV is relatively stationary). A simple solution is to use a single coil whose sensitivity profile barely covers the region of interest, minimizing the imaging FOV and therefore scan-time. We are in the process of testing a new 3T CMR-dedicated system, and are examining several approaches to optimize image quality. Promising initial results were obtained with a flexible receiver coil that generates LV function studies at 3T of diagnostic quality and coverage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local Multi-Channel RF Surface Coil versus Body RF Coil Transmission for Cardiac Magnetic Resonance at 3 Tesla: Which Configuration Is Winning the Game?

INTRODUCTION The purpose of this study was to demonstrate the feasibility and efficiency of cardiac MR at 3 Tesla using local four-channel RF coil transmission and benchmark it against large volume body RF coil excitation. METHODS Electromagnetic field simulations are conducted to detail RF power deposition, transmission field uniformity and efficiency for local and body RF coil transmission....

متن کامل

Cardiac MRI at 3 Tesla - Challenges and Technical Solutions

Introduction Cardiac magnetic resonance (CMR) has rapidly become the imaging method of choice for the diagnosis of cardiovascular disease, and its clinical indications have expanded greatly in the last decade [1]. Although the majority of CMR examinations is still performed at a field strength of 1.5 Tesla, the growing availability of 3 Tesla scanners has resulted in an increasing number of CMR...

متن کامل

Human Brain Imaging at 9.4 Tesla Using a Combination of Traveling Wave Excitation with a 15-channel Receive-only Array

Introduction The combination of a circularly polarized (CP) volume coil for spin excitation with a multi-channel receive-only array is a successful setup for routine human brain imaging at 7 Tesla. For reception, the use of multiple surface coils is important for a high SNR and for the utilization of parallel imaging techniques. For transmission, the main strength of the CP coil is the reasonab...

متن کامل

Impact of neonatal cardiac receive-array coil on SNR and CNR in newborn infants

Background CMR assessments of cardiac function at 3.0 Tesla have been shown to provide more complete data with greater reproducibility than existing echocardiographic methods in newborns [1]. However signal to noise is at a premium in preterm infants. Further advances in image quality and spatial resolution are dependent on maximizing available signal. Prior neonatal CMR imaging has been perfor...

متن کامل

3D myocardial perfusion-CMR using a multi-transmit coil and k-t PCA reconstruction to detect flow limiting coronary stenosis

Background Three-dimensional acquisition methods facilitated by undersampling in space and/or time have been proposed to overcome the limited cardiac coverage of dynamic first pass myocardial perfusion-CMR. Recently, temporally constrained k-t BLAST reconstruction using principal component analysis (k-t PCA) has been proposed to further improve temporal resolution of k-t undersampled data. In a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005