Automated determination of angiotensin-converting enzyme in serum.
نویسندگان
چکیده
This is an adaptation of the Fujirebio "ACEcolor" kit for automated measurement of angiotensin-converting enzyme (EC 3.4.15.1) in serum with the Cobas Fara centrifugal analyzer. The linear range extends to an activity of 110 U/L. Results obtained by the present method and by the manual method were identical, and correlated closely (r = 0.983) with those by Cushman's modified method. The reference interval for 77 adult blood-bank donors was 9-25 U/L (mean 17, SD 4 U/L). Within-run and between-run CVs are 1.7 and 4.0%, respectively. The present method permits rapid, precise, and economical measurement of the enzyme and allows users of a Cobas Fara centrifugal analyzer to introduce a fully automated assay for angiotensin-converting enzyme into their clinical laboratory.
منابع مشابه
Serum Angiotensin Converting Enzyme in Patients with Psoriasis
Background: Controversial data concerning the elevation of serum angiotensin-converting enzyme in psoriasis are reported in the literature. In order to verify whether this abnormality exists in Iranian patients, we performed this study. Method: Serum angiotensin-converting enzyme level was measured in 40 psoriatics. According to clinical forms of psoriasis, patients were further divided into th...
متن کاملStudy of Serum and Tissues Angiotensin Converting Enzyme (ACE) Activity in Rat with Gentamicin Induced Renal Toxicity
The angiotensin I-converting enzyme (ACE) converts the inactive angiotensin I molecule to the active angiotensin II. ACE is rich in epithelium, endothelium, and neuroepithelial cells and it found largely on the brush border of intestine and kidney proximal tubules. ACE also presents in the serum. Some pulmonary and renal toxic drugs change the serum and tissue ACE contents. In this research ACE...
متن کاملP23: The Effects of Captopril, as Angiotensin Converting Enzyme Inhibitor, on LPS-Induced Systemic Inflammation
It has been shown that the renin-angiotensin system (RAS) plays key roles in the inflammation process. Imbalance in the oxidant-antioxidant system is one of the major causes of inflammation. In the present study, the effects of captopril on total and differential WBC, oxidative stress in systemic inflammation produced by lipopolysaccharide (LPS) were investigated. The rats were divided to: cont...
متن کاملThe spectrophotometric determination of human serum carboxypolypeptidase with angiotensin converting enzyme-like activity.
1. A colorimetric method was developed for the direct chemical assay of human carboxypeptidase A (carboxypolypeptidase; EC 3.4.12.2) with angiotensin converting enzyme-like activity in serum or plasma, with the substrate analogue glycyl-L-histidylglycine and the angiotensin converting enzyme substrate angiotensin I (A-I). This method was based on the spectrophototometric determination of histid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 33 7 شماره
صفحات -
تاریخ انتشار 1987